The LEDs on the front panel blink in sequence.
SOL
SOL
SOL
SOL
SOLUTION
UTION
UTION
UTION
UTION
It is normal for this to occur if the inverter switch is On when the DC input is connected to the unit.
If the DC is already connected and the LEDs blink in sequence then the DC input voltage is dropping.
Check for poor connections in the DC wiring, bad battery or a heavy DC load.
SYMPT
SYMPT
SYMPT
SYMPT
SYMPTOM
OM
OM
OM
OM
ON lamp does not light steadily after pushing in the ON-OFF/RESET
Inverter
Switch.
SOL
SOL
SOL
SOL
SOLUTION
UTION
UTION
UTION
UTION
Lamp flashes when utility power is present.
Lamp flashes in Load Demand Waiting mode.
Check/Reset GFCI on the receptacle.
Check battery connections if utility power is OFF.
Check DC fuses if utility power is OFF.
SYMPT
SYMPT
SYMPT
SYMPT
SYMPTOM
OM
OM
OM
OM
ON lamp fully illuminates. AC load does not run.
SOL
SOL
SOL
SOL
SOLUTION
UTION
UTION
UTION
UTION
Check and reset circuit breaker.
Verify AC load and cord are in proper condition.
SYMPT
SYMPT
SYMPT
SYMPT
SYMPTOM
OM
OM
OM
OM
BATTERY LOW lamp illuminates when AC load is applied.
SOL
SOL
SOL
SOL
SOLUTION
UTION
UTION
UTION
UTION
Check battery connections.
Check battery condition.
Recharge battery if voltage is less than 10.5 VDC.
Check AC loads for shorted circuit.
Check the vehicle's alternator charging system for proper operation.
SYMPT
SYMPT
SYMPT
SYMPT
SYMPTOM
OM
OM
OM
OM
OVERTEMP lamp illuminates.
SOL
SOL
SOL
SOL
SOLUTION
UTION
UTION
UTION
UTION
Something has caused the unit to overheat. Check for obstruction of air flow to the cooling fan or from
ventilation holes.
Verify AC load is within unit’s rated
capacity.
SYMPT
SYMPT
SYMPT
SYMPT
SYMPTOM
OM
OM
OM
OM
OVERLOAD lamp illuminates with AC load applied.
SOL
SOL
SOL
SOL
SOLUTION
UTION
UTION
UTION
UTION
Verify AC load is within unit’s rated capacity.
SYMPT
SYMPT
SYMPT
SYMPT
SYMPTOM
OM
OM
OM
OM
DC fuse blows when connecting DC input cables.
SOL
SOL
SOL
SOL
SOLUTION
UTION
UTION
UTION
UTION
Check for reverse polarity: red cable to battery positive (+), black cable to battery negative (-). The
unit may be damaged and require repair service.