LIMITED WARRANTY 

NORTH AMERICAN LIMITED WARRANTY 

Vanner Inc., referred to herein as Vanner, warrants that this product is free from defects in materials and workman-
ship for a period of two (2) years from date of installation or two and one half (2 1/2) years from date of  manufacture, 
whichever is less if and only if the following requirements are complied with: 

1.   The product is installed and checked out properly according to all guidelines, instructions, and checkout 
procedures set forth in the product Installation and Operating Manual. 
2.   The installer records all checkout data required and completes, signs, and returns the warranty 
registration card to Vanner within ten (10) days after installation. 
3.   The product was purchased after January 1, 2000. 
 

Vanner does not warrant its products against any and all defects when: defect is a result of material or workmanship 
not  provided  by  Vanner;  normal  wear  and  tear,  or  defects  caused  by  misuse  or  use  in  contrary  to instructions 
supplied, neglect, accident, reversed polarity, unauthorized repairs and/or replacements. 
 
All  warranties  of  merchantability  and  fitness  for  a  particular  purpose:  written  or  oral,  expressed  or  implied,  
shall extend only for a period of two (2) years from date of installation or two and one half (2 1/2) years from date of 
manufacture, whichever is first.  There are no other warranties that extend beyond those described on the face of this 
warranty. Some states do not allow limitation on how long an implied warranty lasts, so the above limitations may not 
apply to you. 

Vanner  does  not  undertake  responsibility  to  any  purchaser  of  its  product  for  any  undertaking,  representation,  
or warranty made by any dealers or distributors selling its products beyond those herein expressed unless expressed 
in writing by an officer of Vanner. 

Vanner does not assume responsibility for incidental or consequential damages, including, but not limited to, 
responsibility for loss of use of this product, removal or replacement labor, loss of time, inconvenience, expense for 
telephone calls, shipping expense, loss or damage to property, or loss of revenue.  Some states do not allow the 
exclusion or limitation of incidental or consequential damages, so these limitations may not apply to you. 

Vanner  reserves  the  right  to  repair,  replace,  or  allow  credit  for  any  material  returned  under  this  warranty.    
Any damage caused by the customer will be charged or deducted from the allowance. 

All warranty work will be performed at Vanner’s factory, or authorized repair facility utilizing a valid Warranty Authorization 
Number (WAN) prior to repair.    Products  shall  be  delivered  to  Vanner’s  facility,  freight  prepaid  and  fully insured.  
Products repaired under warranty, or replacement parts or products will be returned to North American location prepaid via 
same transportation means and level of service as received, unless directed otherwise.  Prepaid freight policy does not apply 
to locations outside North America.

  

 

Vanner Inc.

 

4282 Reynolds Drive 

Hilliard, Ohio 43026 

Tel (614) 771-2718 

Fax (614) 771-4904 

www.vanner.com

 

 

Specifications Subject to Change 

Copyright 1996, Vanner Inc. 

Printed in the USA 

OM/A96199 REV B   08/2016

 

Summary of Contents for BRAVO 1050

Page 1: ...Contents Introduction 2 General Description 2 Specifications 3 Installation Hardwire Units 4 Operation Hardwire Units 5 6 Installation GFCI Receptacle Units 7 Operation GFCI Receptacle Units 8 9 Troub...

Page 2: ...delay to ensure that full power is available the load is switched back to AC input power and the battery charger activates automatically to recharge the battery Inverter The Bravo QBC10 converts the p...

Page 3: ...F 25 ma Power OFF Frequency _ 60Hz 0 1 Output Waveform Modified Sine Wave BATTERY CHARGER if equipped Charging Capacity AMPS 55 or 27 5 AMPS 1 27 5 or 13 7 AMPS Input voltage VAC 120 VAC 10 Input Curr...

Page 4: ...the negative BLACK DC input cable to the battery negative terminal Connect the positive RED DC input cable to the battery positive terminal 6 Select the proper battery type GEL or flooded lead acid lo...

Page 5: ...ition If utility power is present the ON lamp will FLASH The FLASH indicates the inverter is standing by 4 If utility power is removed or lost and the ON OFF RESET Inverter Switch is in the ON positio...

Page 6: ...Page 6 of 12 BACK PANEL...

Page 7: ...input cables from the inverter charger to the battery If required protect cables where they come into contact with hard or sharp edges 4 Install an inline fuse Bussman ANN 125 for 12 volt application...

Page 8: ...h to the ON position If utility power is present the ON lamp will FLASH The FLASH indicates the inverter is standing by 4 If utility power is removed or lost and the ON OFF RESET Inverter Switch is in...

Page 9: ...Page 9 of 12 FRONT PANEL BACK PANEL...

Page 10: ...ow to the cooling fan or from ventilation holes Verify AC load is within unit s rated capacity OVERLOAD lamp lights when AC load is applied Verify AC load is within unit s rated capacity Try smaller A...

Page 11: ...harging is in progress and the green when the inverter is on or in load demand GFCI TEST RECORD For maximum protection against electrical shock hazard operate test switch on Ground Fault Circuit Inter...

Page 12: ...mplied warranty lasts so the above limitations may not apply to you Vanner does not undertake responsibility to any purchaser of its product for any undertaking representation or warranty made by any...