2.1  General Precautions 

 

Do not expose the charger to direct water spray or snow. 

To reduce the risk of a fire hazard, do not cover or obstruct the ventilation openings. 

Do  not  install  the  charger  in  a  zero  clearance  compartment.  This  may  result  in 

overheating or diminished performance. 

To avoid the risk of fire, electrical shock, or injury to persons, do not use 

attachments not recommended or sold by the Vanner Inc. 

Vanner recommends that all  AC and DC electrical wiring be performed by a licensed 

electrician or a qualified technician to ensure compliance with all applicable national and local 
wiring regulations. 

To  avoid  a  risk  of  fire  and/or  electrical  shock,  always  verify  wiring 

connections  are  in  good  electrical  condition.  All  external  conductors  must  use  proper  wire 
size to avoid dangerous overheating or diminished performance. 

If the charger has been dropped or damaged in any way, do not operate the charger 

until it has been verified to be safe by a qualified technician. 

To reduce the risk of electrical shock, always disconnect the AC and DC connections 

to  the  charger  before  attempting  any  maintenance.  Simply  turning  the  charger  off  does  not 
prevent electrical shock. 

The  charger must  be  properly  grounded  in  accordance  with  local  and  national  codes 

and  ordinances  before  operation.  For  most  installations,  the  negative  (ground)  conductor 
should be bonded to the grounding system at one and only one point in the system. 

For  optimum charger  performance,  battery  temperature  should  be  above  32  degrees 

Fahrenheit.  

Do  not  disassemble  the  charger.  See  the  service  section  of  this  manual  for 

instructions  on  obtaining  service.  Attempting  to  service  the  inverter  yourself  may  result  in  a 
risk of electrical shock, fire and/or loss of warranty. 

Summary of Contents for SP00143

Page 1: ...VANNERIncorporated Owners Manual Max Battery Charger Page 1 Owner s Manual Max Charger 24Volt 42 Amp Three Stage Battery Charger Models SP00155 SPC0182 SPC0184 Models SP00143 SP00180 SP00181 SPC0187...

Page 2: ...and Checkout 5 3 1 Selection of Battery Charger Location 7 3 2 Charger Mounting 8 3 3 Routing and Connecting Battery Charger DC Output Cables 8 4 Battery Charger Operating Procedure 9 4 1 Charger Setu...

Page 3: ...lease contact your dealer or contact Vanner directly at the phone number or email address shown on the back of this manual 1 General Information 1 1 Introduction The Vanner Max Battery Charger is a hi...

Page 4: ...ge Nominal 26 6VDC 27 4VDC Ambient Temperature 40 to 105 F 40 to 40 C Cooling Forced Air 100 CFM 24VDC Fan with front to rear air flow Chassis Steel with durable painted finish Weight 35 lbs Dimension...

Page 5: ...pment tends to produce arcs and sparks during installation To prevent fire or explosion compartments containing batteries or flammable materials must be properly ventilated Safety goggles should alway...

Page 6: ...xternal conductors must use proper wire size to avoid dangerous overheating or diminished performance If the charger has been dropped or damaged in any way do not operate the charger until it has been...

Page 7: ...ediately flood eye with running cold water for at least 20 minutes Get medical attention immediately 5 NEVER smoke or allow a spark or flame near a battery Gases produced by batteries are explosive 6...

Page 8: ...to the Battery s negative terminal 2 Install a fuse in line with the positive battery source to the charger Size fuse at an 80Amp minimum to a 150A maximum 3 Battery cable connections must be clean a...

Page 9: ...ption Stage holds battery voltage at the stated bulk rate for 20 minutes Charger output current will vary as needed to hold battery voltage constant After 20 minutes Absorption Stage ends and Float St...

Page 10: ...her 120VAC is disconnected or battery is disconnected No LED s The charger is OFF and is disconnected from both 120VAC and battery LED Status Indicators for Models SP00155 SPC0182 and SPC0184 LED Char...

Page 11: ...VANNERIncorporated Owners Manual Max Battery Charger Page 11 Owner s Manual Notes...

Page 12: ...tery Charger Page 12 Owner s Manual Vanner Incorporated 4282 Reynolds Drive Hilliard Ohio 43026 1 800 AC POWER 1 800 227 6937 Tel 614 771 2718 Fax 614 771 4904 www vanner com e mail pwrsales vanner co...

Reviews: