VLT Series True Sine Wave Inverter - Owner’s Manual

6

Standard Features

1. True sine wave 120 volt AC output.
2. Resilient electronic protection designed to handle output short circuits and output overloads.
3. Load Demand Feature to conserve DC power under no load conditions. (Not on 600-watt models.)
4. 15 amp GFCI Duplex Receptacle.
5. Automatic shutoff for low or high battery voltage, overload or over temperature with indicator LEDs.
6. Remote control circuit. (Not present on 600-watt models.)
7. Indicator lights for Low Battery Shutoff, Over Temperature Shutoff, Overload and Inverter ON/OFF/Load

Demand status.

8. Thermostatically controlled cooling intake fan.

Definitions

Load Demand Feature and Load Demand Mode:

The Load Demand Feature is an energy conserving feature which allows the inverter to enter the ‘Load Demand
Mode’ whenever the inverter is ON and the AC load has been less than 10 watts for approximately 10 seconds.
While in the ‘Load Demand Mode’ the inverter does not produce 120 volts AC but instead produces pulses of
voltage which the inverter uses to look for a load. When a load greater than 10 watts is sensed, the inverter will
turn fully ON to produce 120 Volts AC. The ‘Load Demand Mode’ is often also described as ‘stand-by mode’ or
‘sleep mode’. While in the ‘Load Demand Mode’ 12-volt models consume approximately 0.1 amps of DC and 24-
volt models consume approximately 0.05 amps of DC.

Load Demand can be turned off by setting factory setup DIP switch #4 to the up position.

Summary of Contents for VLT12-600

Page 1: ...rter VLT12 600 VLT12 1000 VLT12 1500 VLT24 600 VLT24 1000 VLT24 1500 VLT48 1000 VLT48 1500 Owner s Manual D910106 Rev B Rev May 24 2007 60Hz Models VLTE12 600 VLTE12 1000 VLTE12 1500 VLTE24 600 VLTE24...

Page 2: ...ies True Sine Wave Inverter Owner s Manual 2 Vanner Incorporated 4282 Reynolds Drive Hilliard OH 43026 800 AC POWER 800 227 6937 Tel 614 771 2718 Fax 614 771 4904 www vanner com e mail sales vanner co...

Page 3: ...cator 11 Overload Indicator 11 ON OFF Switch 11 Inverter Indicator Light 11 GFCI Duplex Receptacle 11 Section 5 Installation and Setup 12 Unpacking the Inverter 12 Inverter Installation Considerations...

Page 4: ...liarize yourself with the model numbers of the inverter and optional accessories you have purchased before proceeding with this manual If you require additional information please contact your dealer...

Page 5: ...attery Shutdown Over Temperature Shutdown Overload Inverter ON OFF Indicator Overload Short Circuit Reverse Polarity fuse Over Under Input Voltage OverTemp Inverter may be mounted in any orientation M...

Page 6: ...ed cooling intake fan Definitions Load Demand Feature and Load Demand Mode The Load Demand Feature is an energy conserving feature which allows the inverter to enter the Load Demand Mode whenever the...

Page 7: ...nt fire or explosion DO NOT install in confined areas or compartments that contain batteries or flam mable materials WARNING Improper use of this product may result in risk of electrical shock Both AC...

Page 8: ...ries or flammable materials or in locations that require ignition protected equipment This includes any space containing gasoline powered machinery fuel tanks or joints fittings or other connections b...

Page 9: ...Rear entry for negative DC input cable 2 Rear entry for positive DC input cable 3 Rear entry for Remote Control RS 232 Connection 4 Chassis Ground Bonding Lug 5 Cooling Fans Draw air in through intake...

Page 10: ...light is in the red areas of the graph the inverter may shut itself OFF 7 Load Watt Indicator The AC load watt bar graph indicates the power drawn from the inverter It will indicate wattage by loads...

Page 11: ...F switch to the OFF position correct the fault condition and turn the inverter back ON 12 ON OFF Switch and RESET Switch The ON OFF Switch is a two position rocker switch used to turn the inverter ON...

Page 12: ...se the battery cables are connected backward reverse polarity 2 The wiring of your inverter installation should conform to the National Electric Code NEC and any other state or local codes in effect a...

Page 13: ...location should be within 18 of the battery and accessible for visual inspection and replacement If possible locate so the last DC connection can safely be made at the fuse 4 Prepare DC cable ends 5...

Page 14: ...sufficient ventilation DC cables have been connected to the inverter but not yet to the battery AC wiring has been completed and all remote connections have been checked the Start up and Testing proce...

Page 15: ...ble Shooting Procedures The following are the most common questions heard by Vanner service professionals If your situation does not apply to the following categories please contact your local Vanner...

Page 16: ...ove obstructions from air exhaust vents and cooling fan Problem Overload Indicator Light is ON when AC load is applied Check Verify AC load is within the inverter s rated capacity Remove excessive loa...

Page 17: ...CI Test Record For maximum protection against electrical shock hazard operate the Test Switch on the Ground Fault Circuit Interrupter at least once a month and record the values in this supplied table...

Page 18: ...nverter Owner s Manual 18 Vanner Incorporated 4282 Reynolds Drive Hilliard OH 43026 800 AC POWER 800 227 6937 T e l 614 771 2718 Fax 614 771 4904 www vanner com e mail sales vanner com Copyright 2007...

Reviews: