If the water level in the tank is very low and air is being sucked into the feeder outlet tube, the
venturi suction flow is too great for proper operation.  Check the supply water flow and reduce the
venturi suction flow.

For most applications the feeder should be operated at the maximum flow rate of 2.0 gpm.  This
will allow the electronic controller to operate as designed to maintain the proper free chlorine
residual in the water. Follow the recommendations of the controller manufacturer for proper set
up and operation.  At the 2.0 gpm flow rate, the feeder delivers 80 lbs. of available chlorine per
day.  In some instances it may be desirable to reduce this output even when used in conjunction
with electronic controls.  The feeder can be operated at a minimum of 1.0 gpm flow to produce a
maximum output of 27 lbs. of available chlorine per day.

If the water level rises in the solution tank causing the level switch to routinely shut off the feeder,
the inlet water flow is greater then the effluent flow to the venturi. First, verify that the inlet flow is
set to 2.0 gpm using the supplied flow meter when the chlorine feed solenoid valve is open
(water will be spraying into the upper tank). Second, verify that the venturi is extracting 2 to 3
gpm from the lower solution tank. This can be done in a simple fashion by temporarily installing a
flow meter between the feeder effluent and the venturi injector. Adjust the influent and effluent
flow as necessary. In some situations it may be desirable to adjust the float valve in the solution
tank using the bolt located on the float valve arm. For detailed instructions on adjusting the float,
contact your Vantage Representative.

6.  Prior to filling feeder read First Aid, Precautionary Statements, Directions for Use and Storage

and Disposal directions on the Vantage Calcium Hypochlorite Tablet label.  

FILLING THE FEEDER:

1.  Remove feeder lid.   Partially fill the feeder with Vantage Calcium Hypochlorite Tablets.  Do not fill

the feeder completely for the first few days or until proper operation has been observed.  Replace
feeder lid.

2.  

DANGER: 

Use only VANTAGE® Calcium Hypochlorite Tablets.  Never add or use any

other type of chlorinating or brominating chemicals in this feeder. 

Use of any other prod-

uct may lead to explosion or fire possibly leading to personal or bodily injury.  Always
read and follow directions and precautionary statements on the calcium hypochlorite
tablet label.

3.  Ensure that the feeder is operating properly by observing the water level in the tank.  The water

level should remain relatively constant.  The float valve controls the water level in the solution
tank by increasing and decreasing the suction flow from the venturi.  Under normal operating con-
ditions this water level prevents air from being drawn into the pool.  If the water level is low and
the venturi is drawing air into the system, check the supply water line for proper flow rate.

4.  If the water level in the tank gets two high, the level switch will engage the inlet water solenoid

valve and stop all supply water to the feeder.  Check the supply water flow for proper influent flow
rate and check the venturi for proper operation.

5.  Manually test pool water and adjust the feeder and controller until the chlorine level stays

between 1.0 and 5.0 ppm.  

Summary of Contents for ACF-60

Page 1: ...Installation and Operation Manual ACF 60 Automatic Chlorinating Feeder ...

Page 2: ......

Page 3: ...er P2002202 In Line Strainer P2002203 25 of 5 8 OD Tubing P2002225 Feeder Discharge Assembly discharge valve body discharge fitting and locking bolt P601204 Chlorine Feed Assembly sieve plate legs and overflow P601400 Float Assembly P601206 Eductor Model 3144 P2001207 Check Valve P2001208 Booster Pump 3 4 hp P2001209 Inlet Flow 1 0 2 0 gpm Outlet Flow Inlet Flow Inlet Pressure 10 45 psi Maximum Ou...

Page 4: ...der Discharge Assembly 3 Discharge Fitting 4 Float Valve Body 5 Float Assembly 6 Chemical Feed Solenoid Valve 7 Supply Manifold 8 Inlet Water Solenoid Valve 9 Rinse Nozzle 10 Level Switch Assembly 11 Chemical Tank Lid Chlorine Feed Assembly 12 Sieve Plate Overflow 13 Sieve Plate 14 Mining Nozzle 15 Tablet Hopper 16 Locking Bar 17 Locking Pin ...

Page 5: ... an inlet pressure of 10 45 psi The flow rate will be con trolled in the range of 1 0 to 2 0 gpm CONNECTING THE ACF 60 RECOMMENDED INSTALLATION METHODS SIDESTREAM WITH BOOSTER PUMP AND VENTURI see Figure 2 The preferred installation method utilizes a sidestream configured with a booster pump and a ven turi to provide a source of supply water to the feeder as well as a mechanism for delivering the ...

Page 6: ...eturned after the heater The sidestream flow and venturi must be selected to remove a minimum of 2 0 gpm from the feeder at all times When using this installation method make all the connec tions to the ACF 60 as described in the venturi with booster pump installation CONNECT THE FEEDER OVERFLOW The ACF 60 contains an overflow port in both the tablet hopper and the solution chamber The over flow i...

Page 7: ...TIONS The effluent water from the feeder can also be returned directly into the surge pit or vacuum filter pit Erratic controller readings can occur if chlorine is injected into the system prior to the sample line Heater corrosion or scaling can occur if the heater is downstream of the chlorinated water injection point STARTUP AND ADJUSTMENT OF ACF 60 Prior to filling feeder with Vantage Calcium H...

Page 8: ...alves Pool Return Venturi w check valve Inlet Ball Valve Flow Meter Strainer 1 2 Feeder Inlet Flow Control Valve optional H EATER if present P OOL P UMP B OOSTER P UMP F ILTER denotes PVC piping denotes 5 8 outer diameter hose provided ACF 60 Figure 2 Sidestream Installation with Booster Pump and Venturi ...

Page 9: ...ter Flow From Pool Isolation Valves Pool Return Venturi w check valve Inlet Ball Valve Flow Meter Strainer Flow Control Valve optional H EATER if present P OOL P UMP F ILTER denotes PVC piping denotes 5 8 outer diameter hose provided ACF 60 Figure 3 Venturi Installation without Booster Pump ...

Page 10: ...on tank using the bolt located on the float valve arm For detailed instructions on adjusting the float contact your Vantage Representative 6 Prior to filling feeder read First Aid Precautionary Statements Directions for Use and Storage and Disposal directions on the Vantage Calcium Hypochlorite Tablet label FILLING THE FEEDER 1 Remove feeder lid Partially fill the feeder with Vantage Calcium Hypoc...

Page 11: ...eder parts with fresh water The float assembly and other parts can be damaged with rough handling Use caution when cleaning these parts 4 When all parts have been cleaned the interior of the tubing venturi check valve and venturi can be cleaned by adding a mild solution of acid to the feeder and allowing it to be drawn through the piping by the action of the venturi DANGER Be sure that all chlorin...

Page 12: ...valves to prevent water flow into the feeder Do not reopen valves for at least 2 hours following application of shock or superchlorinating product to prevent contamination of tablets WINTERIZATION OF FEEDER If the pool circulation system is shut down during the winter the following procedures are recom mended 1 Operate the feeder until all the Vantage Calcium Hypochlorite Tablets are dissolved 2 F...

Page 13: ...peration Manual Should the warranted equipment prove defec tive in workmanship or material the consumer s sole remedy shall be replacement of defective parts as is herein above expressly provided and under no circumstances shall AllChem Performance Products LP be liable for any loss or damage direct or consequential arising from the use of the warranted equipment Some states do not allow limitatio...

Page 14: ...VTGACF60IOM 060507 Copyright 2007 Document Version 01 AllChem Performance Products LP ...

Reviews: