background image

1” Overflow

(to drain)

1/2” Outlet

to Injector

1/2”

Feeder

Inlet

Water Flow

From Pool

Isolation Valves

Pool

Return

Ball Valve

Ball Valve

Venturi

(w/check valve)

Flow Meter

Solenoid to 

controller

(if applicable)

H

EATER

(if present)

P

OOL

P

UMP

F

ILTER

ACF-8

Figure 3:

Eductor Installation

With Sidestream

Summary of Contents for ACF-8

Page 1: ...Installation and Operation Manual ACF 8 Automatic Chlorinating Feeder...

Page 2: ......

Page 3: ...and supplies may be supplied by the installer The recommended optional installation parts are the ACF 8 Installation kit P008100 includes 25 feet of 5 8 o d tubing four tubing connectors Vantage 1 2 E...

Page 4: ...nd rain This feeder should be installed on a flat level surface capable of supporting its weight when full This feeder is designed to operate at an inlet pressure of 10 45 psi The flow rate will be co...

Page 5: ...rculation pump and the feeder should be elevated above the level of the circulation pump This installation method may result in some air being drawn back into the circulation pump and possibly returne...

Page 6: ...he influent flow is greater then the effluent flow and water will overflow out the overflow drain 6 Prior to filling feeder read First Aid Precautionary Statements Directions for Use and Storage and D...

Page 7: ...o Injector 1 2 Feeder Inlet Inlet Ball Valve Pressure Gravity Installation Figure 1 ACF 8 sump surge pit balance tank or collection tank Effluent feed line Return line Flow Meter Solenoid to controlle...

Page 8: ...r Inlet Water Flow From Pool Isolation Valve Check Valve Pool Return Ball Valve 1 2 Venturi w check valve Flow Meter Flow Control Valve optional 1 2 Solenoid to Controller P OOL P UMP F ILTER Modified...

Page 9: ...Feeder Inlet Water Flow From Pool Isolation Valves Pool Return Ball Valve Ball Valve Venturi w check valve Flow Meter Solenoid to controller if applicable H EATER if present P OOL P UMP F ILTER ACF 8...

Page 10: ...1 Overflow to waste 1 2 Feeder Inlet Return line Flow Meter Solenoid to controller if applicable Inlet Ball Valve Outlet Ball Valve Flow Pump strainer Pressure Suction Installation Figure 4 ACF 8...

Page 11: ...5 Refill feeder with appropriate amount of Vantage Calcium Hypochlorite Tablets replace feeder lid plug in solenoid valve if applicable turn on water and adjust flow rate for proper chlorine output 6...

Page 12: ...Manual Should the warranted equipment prove defec tive in workmanship or material the consumer s sole remedy shall be replacement of defective parts as is herein above expressly provided and under no...

Page 13: ...VTGACF8IOM 060507 Copyright 2014 Document Version 01 AllChem Performance Products...

Reviews: