©Vantage, 8/15/2016 / IS-0536-B
InFusion Power Enclosure — MODEL: IMPE-4(2)-IC36(24) & ISPE-4(2)-IC
page 1 of 6
I N S T A L L A T I O N
V A N T A G E C O N T R O L S . C O M
V A N T A G E I N S T A L L G U I D E S
2168 West Grove Parkway, Suite 300, Pleasant Grove, UT. 84062 USA
Telephone: 801 229-2800
●
Fax: 801 224-0355
InFusion Power Enclosure — MODEL: IMPE-4(2)-IC36(24) & ISPE-4(2)-IC
Overview
Vantage’s
InFusion Main Power Enclosure
(IMPE) and
InFusion
Secondary Power Enclosure
(ISPE) are electrical enclosure
centers composed of high voltage, low voltage
communication, and control devices. All IMPE and ISPE
enclosures contain dimming modules and/or relay modules in
any combination. When setup as a
Main
power enclosure, in
addition to modules, it contains a
Main Enclosure Terminal
Board
(36V or 24V version) making it ready to receive an
InFusion Controller
. When setup as a
Secondary
power
enclosure, in addition to modules, it contains a
Secondary
Enclosure Terminal Board
. High voltage and low voltage
connections inside enclosures are made via clearly labeled
screw terminals. High voltage and low voltage are kept
separate by a built-in barrier in the enclosure’s design.
Main and Secondary Power enclosures are designed to fit
perfectly between conventional framing, however, the
enclosures may also be surface mounted. There are four Main
Power enclosure models and two Secondary Power enclosure
models available.
Enclosure Models
Main Models
Description
IMPE-4-IC36
Up to 4 Modules
Main Enclosure Terminal Board (36V)
IMPE-4-IC24
Up to 4 Modules
Main Enclosure Terminal Board (24V)
IMPE-2-IC36
Up to 2 Modules
Main Enclosure Terminal Board (36V)
IMPE-2-IC24
Up to 2 Modules
Main Enclosure Terminal Board (24V)
Secondary Models
Description
ISPE-4-IC
Up to 4 Modules
Secondary Enclosure Terminal Board
ISPE-2-IC
Up to 2 Modules
Secondary Enclosure Terminal Board
Specifications
Specifications
IMPE-2-ICxx / ISPE-2-IC IMPE-4-ICxx / ISPE-4-IC
Cabinet Dimensions
HWD
35” x 14.5” x 4”
88.9cm x 37cm x 10cm
52” x 14.5” x 4”
132cm x 37cm x 10cm
Door Dimensions
HWD
36” x 15.5” x 0.13”
91.4cm x 39.4cm x 3.3mm
53” x 15.5” x 0.13”
134.6cm x 39.4cm x 3.3mm
Weight
29 lbs / 13.1 kg
42 lbs / 19.1 kg
Number of Modules
Up to 2
Up to 4
Line Feed Terminals
(breaker feeds)
Up to 17
Up to 33
Load Out Terminals
Up to 24
Up to 48
Neutral Terminals
Up to 33
Up to 65
Ground Bar Terminals
Up to 36
Up to 72
*Flash Memory
(via controller)
Color / Finish
Nickel / Powder Coated
Cover
vented, hinged
Wire
copper wire, minimum of 80°C / 176°F insulation
Ventilation
maintained 36” front clearance
Ambient Operating
Temperature
0-40°C / 32-104°F
Ambient Operating
Humidity
5-95% non-condensing
UL, CUL, and CE listed
yes
* InFusion enclosures do not have a flash memory chip built
into the enclosure’s terminal board, instead the InFusion
controller has an MMC/SD flash card port for memory backup
of the project. The project can be backed up to the SD card
when programmed from Design Center software.
Enclosure Features
Identical features for both four and two module models
include:
1.
Hinged door, screws down to lock, allowing easy access
when servicing while helping to prevent unauthorized
access;
2.
Metal flex-tabs to help prevent enclosure from warping
when mounted to uneven framing;
3.
Cut out window in door for easy viewing of controller
status;
4.
Vented for natural convection cooling;
5.
Extra room at the top for high voltage wiring;
6.
Extra room at the bottom for low voltage and high
voltage wiring;
7.
Metal isolation barrier for low voltage wiring (Low voltage
barrier is displayed in transparent format for illustration
only);
8.
Convenient ground terminals;
9.
Screw panel boards for easy connection of new AC
terminal boards via a single screw;
10.
Controller or Secondary Enclosure components cage.
Installation / Enclosure Mounting Instructions
Installation of Vantage products should be performed or
supervised by a
Certified Vantage Installer.
Installation and
maintenance of high voltage devices should only be performed
by
licensed, qualified,
and
competent
personnel having
appropriate training and experience.
CAUTION:
Turn Breakers OFF and Check that no Power is ON
at the AC Terminal Boards when working in the
enclosure or working on lighting fixtures
connected to the Module’s Loads, etc. Do not
allow trimmed wire cuttings to fall into enclosure
components as they may cause damage when
power is restored. Damage from this type of short
will
void
the warranty.
1.
Do not mount enclosures in attics, garages, or
crawlspaces, unless room is properly conditioned to
conform to ambient room temperature and humidity
requirements.
2.
Mount enclosure a minimum of 18” from ceiling or floor.