www.fmiproducts.com
125502-01D
21
OPERATION
Continued
4. Press in and turn control knob clockwise
to the OFF position (see Figure 31).
5. Wait five (5) minutes to clear out any gas.
Then smell for gas, including near the
floor. If you smell gas, STOP! Follow “B”
in the safety information, page 18. If you
don’t smell gas, go to the next step.
6. Press in and turn control knob counter-
clockwise
to the PILOT position.
Press in control knob for five (5) seconds
(see Figure 31).
Note: You may be running this heater
for the first time after hooking up to gas
supply. If so, the control knob may need
to be pressed in for 30 seconds or more.
This will allow air to bleed from the gas
system.
7. With control knob pressed in, press and
release ignitor button. This will light pilot.
The pilot is attached to the front burner. If
needed, keep pressing ignitor button until
pilot lights.
Note: If pilot does not stay lit, contact a
qualified service person or gas supplier
for repairs. Until repairs are made, light
pilot with match. To light pilot with match,
see Manual Lighting Procedure.
8. Keep control knob pressed in for 30 sec
-
Figure 31 - Control Knob and Ignitor
Button Location (Shown as Supplied, No
Control Options)
Flame Adjustment Knob
Control
Knob
Ignitor
Button
onds after lighting pilot. After 30 seconds,
release control knob.
• If control knob does not pop out when
released, contact a qualified service
person or gas supplier for repairs.
Note: If pilot goes out, repeat steps 4
through 8.
9. Slightly push in and turn control knob coun-
terclockwise
to the ON position.
10. Wait one minute and switch selector
switch,
if optional remote control is
used,
to the ON position to light burners.
Note: AUTO is only functional when using
GWMT1 or GWMS2 optional accessories.
Figure 32 - Pilot
(Propane/LP)
Ignitor
Electrode
Pilot
Burner
Figure 33 - Pilot
(Natural)
Pilot Burner
11. Set flame adjustment knob to any level
between HI and LO.
12. To leave pilot lit and shut off burners only:
turn control knob clockwise
to the
PILOT position, or use remote control
manual OFF button, or set selector switch
in the OFF position.
CAUTION: Do not try to ad-
just heating levels by using the
equipment shutoff valve.
WARNING:
If optional remote
control is used, make sure the
selector switch is in the OFF posi
-
tion when you are away from home
for long periods of time. Heater
will come on automatically with
selector switch in the ON position.
TO TURN OFF GAS
TO APPLIANCE
1. Turn control knob clockwise
to the
OFF position.
2.
If Using Optional Hand-Held Remote:
Set
selector switch in the OFF position to
prevent draining battery.
3. Close equipment shutoff valve (see Figure
15, page 15).
MANUAL LIGHTING
PROCEDURE
1. Follow steps 1 through 6 under
Lighting
Instructions
, page 20.
2. Depress control knob and light pilot
with match.
3. Keep control knob pressed in for 30 seconds
after lighting pilot. After 30 seconds, release
control knob. Now follow steps 9 through 11
under
Lighting Instructions
, page 20.