www.fmiproducts.com
121082-01K
19
INSTALLATION
Continued
Figure 27 - Hood Placement
(Model May Vary From Illustration)
HARD-WIRING FIREBOX
NOTICE: A qualified electrician
must connect electrical wiring to
duplex outlet for built-in instal
-
lation. Follow all local codes. In
absence of local codes follow
The National Electric Code ANSI/
NFPA 70
.
The “Handy Box” with duplex outlet is pro-
vided in the firebox located in the lower right
base area.
1. Remove screw holding duplex outlet cover
to handy box. Remove duplex outlet.
2. Route electrical cable through strain relief
and handy box (see Figure 26). Tighten
screws on strain relief.
3. Connect electrical cable to duplex outlet.
Match wire colors to those on duplex out-
let. Be sure to connect the ground wire.
4. Place duplex outlet back into handy box
and secure with screws. Replace outlet
cover.
Strain Relief
Duplex Box/Handy Box
Figure 26 - Hard-Wiring Firebox
Screw
Hood
Figure 28 - Screen Placement
(Model May Vary From Illustration)
Screw
Screen
Screws
INSTALLING FIREPLACE HOOD
AND SCREEN
1. Loosen screws inside top edge of firebox.
Slide notches in hood over screws and
tighten screws (see Figure 27).
2. Install fireplace screen by slipping notches
of fireplace screen over screws on front
of fireplace (see Figure 28).