v 1.01
www.vantecusa.com
Model: MRK-M3501T/MRK-M3503T/MRK-M3504T/MRK-M3505T
LED Indicators (L01)
GREEN
- Power ON
GREEN with ORANGE Blink
- Disk Activity
RED
- Drive Powered, but no data connection on Back
No LED
- No power to the Drive Bay, No drive in the Tray
Power Connector (P01)
Power Connection for the single Bay
Drive Bay – LED – DATA Connectors
Drive Bay 1(B01) – L01 – D01
[Corresponding Drive Bay, LED and DATA Connectors (on Back)]
Note:
1) You can mix SATA and SAS drives in the same storage
unit, but SATA drives HAVE to be connected to SATA
controller and SAS drive HAVE to be connected to SAS
controller SAS drive only support Primary Channel
HDD Activity LED Switch (SW1)
ON
- Show Disk Activity
OFF
- Show Green Power LED (If Drive(s) is in the tray)
LED Indicators (L01-L05)
GREEN
- Power ON
GREEN with ORANGE Blink
- Disk Activity
RED
- Drive Powered, but no data connection on Back
No LED
- No power to the Drive Bay, No drive in the Tray
LED Temperature (T01)
Normal
- Green LED
Exceeding Set Temperature
- Red LED
FAN1
- Fan pull air from the front of the Storage Bays
- Fan Size: 80 x 80 mm Fan
- Fan Status (F01) - will show Red LED if fan Fails
LED Fan Status (F01)
Normal
- Green LED
Fan Failure
- Red LED
Drive Bay – LED – DATA Connectors
Drive Bay 1(B01) – L01 – D01
Drive Bay 2(B02) – L02 – D02
Drive Bay 3(B03) – L03 – D03
Drive Bay 4(B04) – L04 – D04
Drive Bay 5(B05) – L05 – D05
[Corresponding Drive Bay, LED and DATA Connectors (on Back)]
Note:
1) You can mix SATA and SAS drives in the same storage unit,
but SATA drives HAVE to be connected to SATA controller
and SAS drive HAVE to be connected to SAS controller
2) SAS drive only support Primary Channel
Fan Speed Switch (SW1)
LOW
- 2400 rpm
HIGH
- 3000 rpm
HDD Activity LED Switch (SW2)
ON
- Show Disk Activity
OFF
- Show Green Power LED (If Drive(s) is in the tray)
Default Internal Storage Unit Temperature
set to 60°C, you can change the jumper to
either 55°C, 60°C or 65°C Fan Status LED,
Set via FR, F+, FG Temperature Status LED,
set via TR, T+, TG Hard Drive Activity LED
set via +HDD, 1;+HDD, 2;+HDD, 3; +HDD,
4; +HDD, 5
Power Connector (P01, P02)
Dual Power Connection for all 5 Bays
Note:
1) Two Power Connectors must be connected
from the system power supply
2) Power load balance by all attached drives
LED Indicators (L01-L04)
GREEN
- Power ON
GREEN with ORANGE Blink
- Disk Activity
RED
- Drive Powered, but no data connection on Back
No LED
- No power to the Drive Bay, No drive in the Tray
LED Temperature (T01)
Normal
- Green LED
Exceeding Set Temperature
- Red LED
Drive Bay – LED – DATA Connectors
Drive Bay 1(B01) – L01 – D01
Drive Bay 2(B02) – L02 – D02
Drive Bay 3(B03) – L03 – D03
Drive Bay 4(B04) – L04 – D04
[Corresponding Drive Bay, LED and DATA Connectors (on Back)]
Note:
1) You can mix SATA and SAS drives in the same storage unit,
but SATA drives HAVE to be connected to SATA controller
and SAS drive HAVE to be connected to SAS controller
2) SAS drive only support Primary Channel
Fan Speed Switch (SW1)
LOW
- 2400 rpm
HIGH
- 3000 rpm
HDD Activity LED Switch (SW2)
ON
- Show Disk Activity
OFF
- Show Green Power LED (If Drive(s) is in the tray)
Default Internal Storage Unit
Temperature set to 60°C, you can
change the jumper to either 55°C, 60°C
or 65°C Fan Status LED, Set via FR, F+,
FG Temperature Status LED, set via TR,
T+, TG Hard Drive Activity LED set via
+HDD, 4;+HDD, 3; +HDD, 2; +HDD, 1
FAN1
- Fan pull air from the front of the Storage Bays
- Fan Size: 80 x 80 mm Fan
- Fan Status (F01) - will show Red LED if fan Fails
LED Fan Status (F01)
Normal
- Green LED
Fan Failure
- Red LED
Power Connector (P01, P02)
Dual Power Connection for all 4 Bays
Note:
1) Two Power Connectors must be connected
from the system power supply
2) Power load balance by all attached drives
LED Indicators (L01-L03)
GREEN
- Power ON
GREEN with ORANGE Blink
- Disk Activity
RED
- Drive Powered, but no data connection on Back
No LED
- No power to the Drive Bay, No drive in the Tray
LED Temperature (T01)
Normal
- Green LED
Exceeding Set Temperature
- Red LED
Drive Bay – LED – DATA Connectors
Drive Bay 1(B01) – L01 – D01
Drive Bay 2(B02) – L02 – D02
Drive Bay 3(B03) – L03 – D03
[Corresponding Drive Bay, LED and DATA Connectors (on Back)]
Note:
1) You can mix SATA and SAS drives in the same storage unit,
but SATA drives HAVE to be connected to SATA controller
and SAS drive HAVE to be connected to SAS controller
2) SAS drive only support Primary Channel
Fan Speed Switch (SW1)
LOW
- 2400 rpm
HIGH
- 3000 rpm
HDD Activity LED Switch (SW2)
ON
- Show Disk Activity
OFF
- Show Green Power LED (If Drive(s)
is in the tray)
Default Internal Storage Unit Temperature set
to 60°C, you can change the jumper to either
55°C, 60° C or 65°C Fan Status LED, Set via FR,
F+, FG Temperature Status LED, set via TR, T+,
TG Hard Drive Activity LED set via +HDD, 3;
+HDD, 2; +HDD, 1
FAN1
- Fan pull air from the front of the Storage Bays
- Fan Size: 70 x 70 mm Fan
- Fan Status (F01) - will show Red LED if fan Fails
LED Fan Status (F01)
Normal
- Green LED
Fan Failure
- Red LED
Power Connector (P01, P02)
Dual Power Connection for all 3 Bays
Note:
1) Two Power Connectors must be connected
from the system power supply
2) Power load balance by all attached drives
D01
P01
FAN1
FAN1
FAN1
L01
L03
L02
L01
L03
L04
L02
L01
L03
L04
L04
L02
L01
B01
B03
T01
F01
T01
F01
F01
D05
D04
D03
D02
D01
T01
B02
B01
B03
B04
B02
B01
B01
B02
B03
B04
B05
SW1
SW1
D01
D02
D03
D01
D02
D03
D04
P01
P01
P02
P02
P02
SW2
P01
SW1
SW2
SW1
SW2