background image

FPA-C34, FPA-W34   

 

14

17

 

 

4.

 

Tips

 

Waste

 

Disposal

 

It

 

is

 

recommended

 

to

 

disassemble

 

the

 

device

 

before

 

abandoning

 

it

 

in

 

conformity

 

with

 

local

 

regulations.

 

Please

 

ensure

 

that

 

the

 

abandoned

 

batteries

 

are

 

disposed

 

according

 

to

 

local

 

regulations

 

on

 

waste

 

disposal.

 

Do

 

not

 

throw

 

batteries

 

into

 

fire

 

(explosive)

 

or

 

put

 

in

 

common

 

waste

 

canister.

 

Products

 

or

 

product

 

packages

 

with

 

the

 

sign

 

of

 

“explosive”

 

should

 

not

 

be

 

disposed

 

like

 

household

 

waste

 

but

 

delivered

 

to

 

specialized

 

electrical

electronic

 

waste

 

recycling/disposal

 

center.

 

Proper

 

disposal

 

of

 

this

 

sort

 

of

 

waste

 

helps

 

avoiding

 

harm

 

and

 

adverse

 

effect

 

upon

 

surroundings

 

and

 

people’s

 

health.

 

Please

 

contact

 

local

 

organizations

 

or

 

recycling/disposal

 

center

 

for

 

more

 

recycling/disposal

 

methods

 

of

 

related

 

products.

   

Comply

 

with

 

the

 

following

 

safety

 

tips:

 

 

Do

 

not

 

use

 

in

 

combustible

 

and

 

explosive

 

environment

 

 

Keep

 

away

 

from

 

combustible

 

and

 

explosive

 

environment

 

for

 

fear

 

of

 

danger.

   

Keep

 

away

 

from

 

all

 

energized

 

circuits.

   

Operators

 

should

 

not

 

remove

 

enclosure

 

from

 

the

 

device.

 

Only

 

the

 

group

 

or

 

person

 

with

 

factory

 

certification

 

is

 

permitted

 

to

 

open

 

the

 

enclosure

 

to

 

adjust

 

and

 

replace

 

the

 

structure

 

and

 

components

 

of

 

the

 

device.

 

Do

 

not

 

change

 

components

 

unless

 

the

 

power

 

cord

 

is

 

removed.

 

In

 

some

 

cases,

 

the

 

device

 

may

 

still

 

have

 

residual

 

voltage

 

even

 

if

 

the

 

power

 

cord

 

is

 

removed.

 

Therefore,

 

it

 

is

 

a

 

must

 

to

 

remove

 

and

 

fully

 

discharge

 

the

 

device

 

before

 

contact

 

so

 

as

 

to

 

avoid

 

injury.

   

 

Unauthorized

 

changes

 

to

 

this

 

product

 

or

 

its

 

components

 

are

 

prohibited.

     

In

 

the

 

aim

 

of

 

avoiding

 

accidents

 

as

 

far

 

as

 

possible,

 

it

 

is

 

not

 

allowed

 

to

 

replace

 

the

 

system

 

or

 

change

 

components

 

unless

 

with

 

permission

 

and

 

certification.

 

Please

 

contact

 

the

 

technical

 

department

 

of

 

Vantron

 

or

 

local

 

branches

 

for

 

help.

   

 

 

Pay

 

attention

 

to

 

caution

 

signs.

   

Caution

 

signs

 

in

 

this

 

manual

 

remind

 

of

 

possible

 

danger.

 

Please

 

comply

 

with

 

relevant

 

safety

 

tips

 

below

 

each

 

sign.

 

Meanwhile,

 

you

 

should

 

strictly

 

conform

 

to

 

all

 

safety

 

tips

 

for

 

operation

 

environment.

   

Notice

 

Considering

 

that

 

reasonable

 

efforts

 

have

 

been

 

made

 

to

 

assure

 

accuracy

 

of

 

this

 

manual,

 

Vantron

 

assumes

 

no

 

responsibility

 

of

 

possible

 

missing

 

contents

 

and

 

information,

 

errors

 

in

 

contents,

 

citations,

 

examples,

 

and

 

source

 

programs.

   

Vantron

 

reserves

 

the

 

right

 

to

 

make

 

necessary

 

changes

 

to

 

this

 

manual

 

without

 

prior

 

notice.

 

No

 

part

 

of

 

this

 

manual

 

may

 

be

 

reprinted

 

or

 

publicly

 

released

 

in

 

for

 

FCC

 

Warning

 

Summary of Contents for FPA-C34

Page 1: ...FPA C34 FPA W34 1 17 FPA C34 FPA W34 User s Manual ...

Page 2: ...17 2 V1 1 Add DIP Switch explain 2015 01 25 3 V1 2 Add some pictures to function 2015 02 01 4 V1 3 Change some pictures to function 2015 02 04 5 V1 4 Statement Vantron is the manufacturer to the device and SMC is the customer of the device 2016 7 19 6 V1 5 Require professionally install antennas and use antennas specified by the manufacturer 2016 8 3 ...

Page 3: ...s for Power Cables and Accessories 5 2 Overview 7 2 1 Introduction 7 3 M2M Gateway FPA C34 FPA W34 Hardware Instructions 9 3 1 Product Appearance 9 3 5 Interface Description 10 3 5 1 Power Interface 10 3 5 2 Ethernet Interface 10 3 5 3 RS232 or RS485 Connector 11 3 5 3 DIP Switch for select 11 3 5 3 DIP Switch for boot 11 3 5 6 LED 12 3 5 7 Micro SIM Card 12 3 5 8 DEBUG 12 3 5 9 Renew button 12 3 ...

Page 4: ...logy Vantron E mail sales vantrontech com The trademarks and registered trademarks in this manual are properties of their respective owners No part of this manual may be copied reproduced translated or sold No changes or other purposes are permitted without the prior written consent of Vantron Vantron reserves the right of all publicly released copies of this manual 1 2 Notes Applicable notes are ...

Page 5: ... attention to the product labels safety instructions printed on silk screens Do not try repairing this product unless declared in this manual Keep away from heat source such as heater heat dissipater or engine casing Do not insert other items into the slot if any of this device Keep the ventilation slot ventilated for cooling System fault may arise if other items are inserted into this device Inst...

Page 6: ...t use spray detergent Clean with a damp cloth Do not try cleaning exposed electronic components unless with a dust collector Support for special fault Power off and contact technical support personnel of Vantron in case of the following faults The device is damaged The temperature is excessively high Fault is still not solved after the operation according to the manual ...

Page 7: ...t stably and assemble its antenna s for WLAN BlueTooth CELL and possible GPS if the device is configured for CELL function maybe you need to activate the SIM card against proper carrier and then please insert correct 12 24V DC cable to the power jack of the device the device will be powered up and the PWR LED lighting indicates the system boots up The device have a standard RJ45 Ethernet port whic...

Page 8: ...FPA C34 FPA W34 8 17 ...

Page 9: ...FPA C34 FPA W34 9 17 3 M2M Gateway FPA C34 FPA W34 Hardware Instructions 3 1 Product Appearance Front Side View Light Side View ...

Page 10: ...Power input range 12 24V 2 Ground 3 Shell ground 3 5 2 Ethernet Interface Standard RJ45 interface supporting 10M 100M Full Half Duplex this is a standard RJ45 Ethernet port Pin Description Remarks 1 ETH_TX O 2 ETH_TX O 3 ETH_RX I 4 ETH_RX I 5 ETH_CT 6 ETH_CT 7 NC 8 DGND P 9 LEDG IO 10 LEDG IO 11 LEDG 12 LEDG PIN1 ...

Page 11: ... 5 3 DIP Switch for select Bit Description Single 1 ON have matched resistance of 120 ohm OFF have no Term 2 ON have pull up resister of 510 ohm OFF have no Bias 3 ON have pull down resister of 510 ohm OFF have no Bias 4 ON select RS232 OFF select RS485 Select RS232 or RS485 3 5 3 DIP Switch for boot Note 1 off 0 on Bit 4 1 Description 1111 Boot for SD MMC 1011 Boot for NAND ...

Page 12: ...ceive data it can blink 3 5 7 Micro SIM Card Push the SIM Card and Push again it can put in or put out 3 5 8 DEBUG CONN Pin header 1x4x2 0 TH User can show the debug message and use keyboard input debug command It s TTL level we need a Uart debug board when we use it Pin Description 1 3 3V 2 TTL_TXD 3 TTL_RXD 4 DGND 3 5 9 Renew button Renew button long press this button will restore the factory se...

Page 13: ...FPA C34 FPA W34 13 17 3 5 12 SD MMC socket This is standard SD card socket user can save data on this storage ...

Page 14: ...d to open the enclosure to adjust and replace the structure and components of the device Do not change components unless the power cord is removed In some cases the device may still have residual voltage even if the power cord is removed Therefore it is a must to remove and fully discharge the device before contact so as to avoid injury Unauthorized changes to this product or its components are pr...

Page 15: ...rence to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving a...

Page 16: ...mpts L exploitation est autorisée aux deux conditions suivantes 1 l appareil ne doit pas produire de brouillage et 2 l utilisateur de l appareil doit accepter tout brouillage radioélectrique subi même si le brouillage est susceptible d en compromettre le fonctionnement RF exposure warning This equipment must be installed and operated in accordance with provide instructions and the antenna used for...

Page 17: ...China Office Chengdu Vantron Technology Ltd Address 6th floor 1st building No 9 3rd WuKe East Street WuHou District Chengdu P R China 610045 Tel 86 28 8512 3930 3931 8515 7572 6320 Email sales vantrontech com cn US Office Sierra Monitor Corporation Address 1991 Tarob Court Milpitas CA 95035 6840 UNITED STATES Tel 1 408 964 4447 Fax 1 408 262 9042 ...

Reviews: