Vapor Expert(PY-001)Portable Nebulizer – Instruction Manual 

 

 

 

Do not add medicine over the indicated line marked on medical cup (8c.c marking). 

 

Do not disassemble or make any modification on this appliance. 

 

 
2. Under using 

 

Children or disable patients should be assisted by adults or medical personnel when 
using this appliance. 

 

Do not use this appliance under a high humid environment (>85% RH) 

 

Do not use this product if the medical cup without any medicine. 

 

Keep the appliance in flat position and steady during operation to avoid spillage. 

 

Do not open the cover of medical cup during operation. 

 

Keep eyes away from the mist output. 

 

Treatment period please follow the doctor’s advice. 

 

Different patients should use individual clean medical cups and mouth pieces to 

 

avoid cross infection. 

 

Some medicine dose not nebulizes well, please consult with your doctor. 

 

This  appliance  has  a  low-battery  indicator.  When  the  indicator  light  is  green,

 

the 

power  is  good  for  working.  When  the  power  light  turns  to  orange,  the  battery  is                   
become  weak,  but  you  still  can  use  product,  however  you  may  need  to  replace 
battery  soon.  If the  power light is turns  red  it  means voltage is too low  to  operate, 
please replace the battery immediately.   

 

During  using  this  appliance,  if  any  irregularity  or  discomfort  is  observed,  please 
discontinue use this appliance. 

 

This  product  has  built-in  a  20-minute  shutoff  timer.  If  it  cannot  be  shutoff 
automatically, discontinue using and consult your dealer for help. 

 

If product detects no medicine in the medical cup, the LED indicator will turn red and 
flash four times then shutoff automatically 

 

When under using, you can use the product in any angles. But, make sure medicine 
has good contact with mesh.

 

 

 
3. After using 

 

Please clean all parts after each usage and do follow instruction in the 
manual. 

 

Do  not  immerse  this  appliance  in  water  when  cleaning  to  avoid 
damaging any electrical parts. 

 

Do  not  store  this  appliance  in  direct  sunlight,  outside  our  suggestion 
storage temperature and humidity environment. 

 

Keep this product from the reach of children.   

 
 
 
 
 
 
 

Summary of Contents for PY-001

Page 1: ...Vapor Expert PY 001 Portable Nebulizer English 2011 10 21 Instruction Manual ...

Page 2: ...under the guidance of qualified medical experts Environment This product is intended for use in a medical facility such as Hospital clinic and doctor s office in a room of general household and in open air environment with a roof Durable period Durable periods are as follows Durable period may vary depending on usage environment Main body 1year Medical cup 1year Mouth piece 1year Mask 1year Precau...

Page 3: ...asily to carry 3 Ultrasonic vibration which produces 100 000 120 000 vibrations per second 4 After 20 minutes continuously operation or when the medical cup is no medicine the appliance will automatic shutdown 5 Built in low battery indicator 6 No matter use the product in different angle that still can operate normally in short term When put the product upside down medicine cannot contact to mesh...

Page 4: ...en the power is good for working When the power light turns to orange the battery is become weak but you still can use product however you may need to replace battery soon If the power light is turns red it means voltage is too low to operate please replace the battery immediately During using this appliance if any irregularity or discomfort is observed please discontinue use this appliance This p...

Page 5: ...lso showing is there still have medicine inside the medical cup If there is no medicine inside indicator light will turn red and flash four times before turn off automatically 3 Medical Cup Contain the medicine Suggestion Replace a new medical cup per year 4 Push button push here to release the medical cup from the main body 5 Medical cup cover open here to pour the medicine 6 Mouthpiece or Mask 7...

Page 6: ...ied by using different brands of battery Suggestion Use Alkaline batteries or Ni MH rechargeable Batteries option 1 Remove batteries if the unit is not in use for long periods Failure to do so could result in damage due to battery leakage 2 Discard the waste batteries according to local law 3 Open the medical cup cover and pour the medicine into the medical cup and close the cover completely 4 Ins...

Page 7: ...n the following parts 1 Remove the medical cup and mouthpiece or mask Discard all remaining medicine in the cup Open the medical cap and discard all remaining medicine Pour in some hot water and close the cover completely Press the power button and operate 1 2minutes to discard all remaining medicine completely Ensure medicine be cleaned completely after each using otherwise it could cause mesh bl...

Page 8: ... red indicator light is on the battery power is too low Please replace the battery immediately 2 Discard the waste batteries according to local law 1 Check the battery is installed correctly Open battery cover and check if the battery electrode is rusted or not Cannot nebulize or not enough mist output 1 Check if the medical cup is filled with appropriate amount of medicine 2 The mesh in medical c...

Page 9: ...anual The accessories Model No Size Child Mask PY 001 MS 87 22 x 64 35 x 57 mm Adult Mask PY 001 ML 124 x 77 x 68 5 mm Mouth Piece PY 001 MP 43 x 27 5 mm Medical Cup Gray PY 001 MC 54 x 43 99 x 38 50 mm Medical Cup Blue PY 001 B MC 54 x 43 99 x 38 50 mm ...

Page 10: ...Vapor Expert PY 001 Portable Nebulizer Instruction Manual ...

Page 11: ...Vapor Expert PY 001 Portable Nebulizer Instruction Manual ...

Page 12: ...therapy equipment Part 1 Nebulizing systems and their components Annex CC 3 using the type test method Particle Size MMAD 4 98um Sound Less than 30db Aerosol Output 0 2 mL min SYMBOLS DESCRIPTION Warning Symbol for Type BF applied part Direct current Read the documentation symbol Batch Symbol Serial number Symbol Manufacturer EC Representative Symbol ...

Page 13: ...ght Low battery indication 2 0V red light Operation environment 10 40 C 30 80 RH Storage Transportation environment 20 70 C 85 RH Nebulization rate 0 2mL min 1 0mL min Max Particle size 5um Time AUTO OFF Power on operate 20 min Then auto off Nebulizer auto off No medication Medication bottle volume 2 8 mL Max Ultrasonic Oscillation Frequency 103 KHZ 123 KHZ 1K Reusable parts life Medical cup mask ...

Page 14: ...ch Co Ltd 2F No 285 Sec 2 Tiding Blvd Neihu Dist Taipei City 11493 Taiwan R O C Tel 886 2 2627 0630 Fax 886 2 2627 0636 E mail service puyuan bio com Ms Chien Wei Lin Breitachstr 56 D 73547 Lorch Germany Tel 49 7172 9350580 Fax 49 7172 9350589 E Mail linchienwei gmail com ...

Reviews: