4 Wiring
Varec, Inc.
25
Expansion Junction Box
The expansion junction box provides 20 terminals using pluggable terminal connections and
includes two earth ground terminals. The expansion junction box terminal board has
dedicated terminals for 4 contact outputs and 4 limit switches. The following figure shows the
typical Expansion Junction Box.
Note
The terminals and labels will vary based on the options selected.
HART Master Active/Passive Configuration
Switch 6 (SW6) on the Communications Board sets the 2920 FTT HART bus to Active (A) or
Passive (P).
• With SW6 set to A, the 2920 will supply voltage to the HART bus. This is the default.
• With SW6 set to P, a HART slave device with an active output will supply voltage to
the HART bus.
T9
T10
TB1
TB2
T3
LS1 NC
LS1 COM
LS2 NC
LS2 COM
LS3 NC
LS3 COM
DI 4
DI COM
LS4 NC
DO 1A
DO 1B
DO 2A
DO 2B
DO 3A
DO 3B
DO 4A
DO 4B
08-013220