Varec, Inc.
15
4532
Mounting
4. Draw the tensioning wire through the wire hook on the tank bottom.
5. Wrap the tensioning wire twice around the hole on the bottom hook, tighten it and
wrap the provided wire around it (see Figure 5-3).
Figure 5-3: Tensioning wire mounting
6. Fix the mounting flange of the 4532 ATC to the nozzle on the tank top using bolts.
Note!
Please keep the compression of the spring at 35 to 37 mm (1.38 to 1.47).
If you compress the spring over 35 to 37 mm, it may cause damage to the sensor.
7. Draw the end of the tensioning wire as much as possible by hand and foot (see
Figure 5-4)
8. Bend the wire and fix it using the nut.
9. Cut the excess wire.
10. Screw the nut to compress down the spring of the top anchor 35 to 37 mm.
11. Cover the top anchor.
Figure 5-4: Top anchor mounting
Flexible tube
Wire hook
Provided wire
Tensioning wire
Bottom hook
35~37mm