Liquid Level Indicator
10
Installation and Operations Manual
Note
Install a Varec manhole or inspection hatch, if there is none located within arms
reach of the tape pipe location. Refer to In-service Tank Installations later in this section
for hatch and manhole installations.
Locate the float at a position inside of the tank where agitation on it will be at a minimum.
Install a deflector if the product stream is close to the float. Contact Varec if agitators will cause
excess float disturbances. Vertical pipe runs must be plumbed and perpendicular to prevent
the tape from binding inside the pipe.
The user must attach the gaugeboard to the tank by welding or bolting the supplied
gaugeboard support brackets. If the environment is such that welding cannot be performed,
the user can construct a support structure with 3-inch [76 mm] pipe or conduit close to the
outside of the tank. The brackets can be welded to the support structure at another location,
if necessary, and the pipe structure assembled at the tank site. Refer to In Service Tank
Installations later in this section for additional details.
Warning
The user should comply with all applicable regulations, codes, and standards.
For safety precautions, the user should refer to the appropriate industry or military
standards.
Table 6: Typical Tools, Equipment, and Materials List
Tool/Equipment
Breathing equipment
Pick
Cable cutter
Pipe cutter
Chalk
Pipe taps/dies
Chalk line
Pliers
Clean drop cloth
Plumb bob
Compass
Protractor
Drill bits
Screwdrivers
Electric drill
Sheet metal shears
Hole cutters
Shovel
Level
String
Light oil
Tank hand gauge
Loctite 262
Vice
Loctite 567
Welding equipment
Long measuring tape
Wrenches
Summary of Contents for 6700
Page 2: ......
Page 25: ...Installation Varec Inc 17 Figure 8 Half Travel Cone Roof Tank Installation 16 50 419...
Page 39: ...Installation Varec Inc 31 Figure 15 Bolted Tank Installation 16 50 419...
Page 51: ...Installation Varec Inc 43 Figure 20 Severe Service Cone Roof Tank Installation 12 50 318...
Page 70: ...Liquid Level Indicator 62 Installation and Operations Manual...
Page 73: ......