2
VL3600 PROFILE IP
Quick Start Guide
REV A 06/28/22
To connect power and data:
Step 1. Connect data cable from console to first luminaire in chain at DATA IN connector.
Step 2. If required, connect additional data cables from DATA THRU connectors to DATA IN connectors
of remaining luminaires in link.
Step 3. At last luminaire in link, install male termination connector at DATA THRU connector. (Luminaires
and other devices on the same DMX chain may not function properly without termination.)
Step 4. Connect AC Input Cable connector to power input source.
Step 5. Dress AC input and data cables and secure them so that they will not interfere with luminaire
head and yoke movement.
CURRENT VERSUS VOLTAGE
TABLE 1
provides the luminaire’s current draw at specific
voltages. Total luminaire current is calculated with the
lamp on and all motors sequencing.
CONNECTING DATA
A maximum of 32 luminaires may be connected in any
one DMX data link.
NOTE:
This maximum limit applies to the luminaire “daisy
chain” only. Your system or console may require fewer
luminaires on a single data link path. Consult your console
documentation for more information.
AC VOLTAGE
AT 60HZ
TOTAL
LUMINAIRE
CURRENT
TOTAL
LUMINAIRE
POWER
PFC
120V
12.66a
1505W
0.996
180V
8.22a
1475W
0.988
208V
7.12a
1472W
0.987
230V
6.32a
1460W
0.987
240V
6.12a
1445W
0.983
264V
5.58a
1440W
0.980
277V
5.38a
1435W
0.966
TAbLE 1. CURRENT VS. VOLTAGE (1000W LED)