Test X05 - Brightness Iris
When test X05 is executed, the brightness iris is driven closed until the
sensor is engaged. The iris is then cycled almost fully open and then
closed. Failure is indicated if the iris will not move or stops prematurely.
Parameter settings for test X05 are as follows:
Parameter Test setting
Test Results
005
2 seconds from full open to full close
105
same as above
205
same as above
305
4 seconds from full open to full close
405
10 seconds from full open to full close
505
20 seconds from full open to full close
605
1 min. 30 sec. from full open to full close
705
5 minutes from full open to full close
805
open
905
closed