C
HAPTER
3. M
AINTENANCE
P
ROCEDURES
3-19
02.9631.0010
CONFIDENTIAL
15 Jan 98
Test X06 - Color Wheel 1 with Sensor
When test X06 is executed, color wheel 1 is cycled until it encounters the
sensor. The wheel stops, rotates away from the sensor, and back again. If
the sensor is not detected, the wheel continues to cycle until the fault is
corrected or the test setting is changed.
Parameter settings for test X06 are as follows:
Parameter Test setting
Test Results
006
5 sec. rotation of wheel forward and
reverse. Stop at open white.
106
2 sec. rotation of wheel forward and
reverse. Stop at open white.
206
cycles between red and light blue.
306
continuous step through color wheel
406
reverse rotation 5X; forward rotation 5X
506
slow reverse steps through color wheel
filter by filter
606
15 sec. 2X reverse, 15sec. 2X forward
706
slow reverse rotation
806
stop at open white
906
high speed wheel spin