VL6500 WASH

QUICK START GUIDE

Summary of Contents for VL6500 WASH

Page 1: ...VL6500 WASH QUICK START GUIDE ...

Page 2: ...ollowing optional and or replacement items can be ordered directly from your Authorized Vari Lite Dealer When ordering please order by the Vari Lite part number VARI LITE PART NO ACCESSORY PCT1BE AC Input Cable Neutrik powerCON True1 with Bare End no connector 1 Meter PC1GTL208 AC Input Cable Neutrik powerCON True1 with Twist Lock Male 250V 1 Meter PCT1GP AC Input Cable Neutrik powerCON True1 with...

Page 3: ... CONNECTION green yellow AC ground blue AC neutral brown AC line International Harmonized Standard WARNING DO NOT connect to three phase service in countries with 240 volt power For single phase power at 208 240 V RMS CONNECTION PIN AC neutral X AC line Y Ground earth G For three phase power at 208 V RMS CONNECTION PIN Phase 1 X Phase 2 Y Ground earth G WARNING It is not recommended to power any V...

Page 4: ...t suitable sources of power because their output modifies the AC wave form This may work for a short time but will eventually result in power problems luminaire mis operation and or failure and may void the luminaire s warranty CONNECTING DATA AND POWER A maximum of 32 luminaires may be connected in any one DMX data link NOTE This maximum limit applies to the luminaire daisy chain only Your system ...

Page 5: ...ed menu item is reached press the desired Menu Button to display the menu options and to navigate and configure the menu options as required To navigate and access menu settings selections Step 1 Make sure unit is powered and turned on Step 2 Press ESC to access menu categories Step 3 Use four Arrow buttons to navigate through the various options and settings Step 4 Once menu item is reached press ...

Page 6: ...re operational information of the luminaire The Status Bar contains the following information LAMP indicates current lamp state ON or OFF SHDN indicates shutdown time in hours NO indicates NO shutdown time ERRORS Displays a number indicating the total amount of current errors When errors are present messages will appear in Red text When no errors are present NO will display ADDR Displays the curre...

Page 7: ...gerous voltages and damage the device A qualified electrician must perform this installation WARNING Refer to National Electrical Code and local codes for cable specifications Failure to use proper cable can result in damage to equipment or danger to personnel WARNING This equipment is intended for installation in accordance with the National Electric Code and local regulations It is also intended f...

Page 8: ...oronation Road Park Royal London NW10 7QP United Kingdom Tel 44 020 8965 3209 OCEANIA 14H Vega Place Rosedale Auckland 0632 New Zealand Tel 64 9 481 0100 VL6500 WASH Quick Start Guide Document no Version date June 6 2019 2019 Signify Holding All rights reserved All trademarks are owned by Signify Holding or their respective owners The information pro vided herein is subject to change without notic...