03-914648-00:5
163
Local Automation
Introduction
This section of the manual deals with local automation from the 3800
keyboard / display. For information regarding automation control from the
Star Workstation please refer to the Star Workstation documentation. Local
automation control from the 3800 keyboard is completely independent from
Workstation automation control and was designed for those users who do
not use the Star Workstation.
Note:
If Local 3800 Automation is selected on a 3800 that has a Star Workstation
connected, the Star Workstation will be disconnected from the 3800. In this mode
the 3800 and autosampler, if installed, cannot be controlled from the Star
Workstation and data cannot be transmitted over the Ethernet. To restore Star
Workstation communication the Manual Injection mode must be selected in
Automation Select / Edit and then Remote Control must be enabled in the
Instrument Menu section of the 3800 keyboard.
3800 local automation consists of two distinct types of automation control.
One type refers to automation using a device that can be controlled from the
3800 through a communications interface called a Sample Introduction
Device. This type of automation is known as
addressable automation
. The
most common example of addressable automation is control of the Varian
8400 GC AutoSampler.
Addressable
e.g., 8400 AutoSampler
Non- Addressable
e.g., Gas Sampling Valve
Single Method
Multiple Injections
Single Method
Multiple Injections
Method Sequence
Multiple Injections
and Multiple Methods
Method Sequence
Multiple Injections, Multiple Methods,
and Multiple Sequences
3800 Local Automation
Figure 29 3800 Local Automation
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com