4-1
VHS-4, VHS-6 and VHS-250 Diffusion Pumps
D
R
A
FT 3/9
/
05
Section 4. Troubleshooting
4.1 Leakage
Analysis of general operational experience with diffusion pumps indicates that certain
locations are more prone to vacuum leaks. The following locations should be checked first
if leakage is the suspected cause of poor system performance:
❑
Inlet and foreline connections
❑
Drain and fill plugs
❑
Other compression fittings, such as high vacuum gauges in the system
❑
Threaded connections, such as foreline gauge
4.2 Outgassing
High vacuum systems, even without external leakage, can also exhibit high gas loads due to
outgassing from internal surfaces or processes. The pressure in the system is a result of gas
load divided by pumping speed (P = Q/S). If the gas load (Q) exceeds the maximum
throughput capability of the diffusion pump, the diffusion pump will not function and the
pumping action will essentially be performed by the mechanical backing pump.
To estimate gas load:
After evacuation, isolate the system from all pumps and measure the rate of pressure
rise. The gas load created by the system can be estimated as:
Where:
V
is the isolated volume
∆
P
is the pressure rise, and
∆
t
is the time period of measurement
Q = V x
∆
P
∆
t
Summary of Contents for VHS-250
Page 2: ...Copyright 2005 Vacuum Technologies VHS 4 VHS 6 and VHS 250 Diffusion Pumps ...
Page 4: ...VHS 4 VHS 6 and VHS 250 Diffusion Pumps This page intentionally left blank ...
Page 6: ...VHS 4 VHS 6 and VHS 250 Diffusion Pump This page intentionally left blank ...
Page 8: ...VHS 4 VHS 6 and VHS 250 Diffusion Pumps This page intentionally left blank ...
Page 10: ...VHS 4 VHS 6 and VHS 250 Diffusion Pumps This page intentionally left blank ...
Page 12: ...VHS 4 VHS 6 and VHS 250 Diffusion Pumps This page intentionally left blank ...
Page 34: ...VHS 4 VHS 6 and VHS 250 Diffusion Pumps This page intentionally left blank D R A F T 3 9 0 5 ...
Page 50: ...VHS 4 VHS 6 and VHS 250 Diffusion Pumps This page intentionally left blank D R A F T 3 9 0 5 ...
Page 56: ...VHS 4 VHS 6 and VHS 250 Diffusion Pumps This page intentionally left blank D R A F T 3 9 0 5 ...
Page 59: ......