Page 9
2.4 CONNECTION PROCEDURE
For the following connection procedures, refer to figures 1.
2.4.1 - Input power
Use a screwdriver to remove cable knock-outs for the
installation of cables on the CPS-3M.
2.4.1.1 - 115 VAC
Make sure that the line voltage selector switch is set to
115 VAC
. See figure 1 for wiring.
2.4.1.2 - 230 VAC
Make certain that the line voltage selector switch is set to
230 VAC. See figure 1 for wiring.
2.4.2 - Zone 1 Actuator motor
Zone 1 provides two relays which control an actuator motor
connected to an air inlet. The first relay controls air inlet
opening and the second controls air inlet closing. The
current rating is 6 Amps (inductive).
See figure 1.
2.4.3 - Zone 2 Actuator motor
Zone 2 provides two relays which control an actuator motor
connected to an air inlet. The first relay controls air inlet
opening and the second controls air inlet closing. The
current rating is 6 Amps (inductive).
See figure 1.
2.4.4 - Wiring diagram for a three phase motor
See figure 1a
2.4.5. - Wiring diagram for a four wire motor
See figure 5
CHAPTER 2 - INSTALLATION
Do not power up the CPS-3M until all connections have
been completed!
www.monitrol.com