MAIN SET POINT
The desired room temperature. Other temperature
settings on the ECS 5M are relative to the main set point
temperature.
RELATIVE TEMPERATURE
A value added to or subtracted from the main set point
which results in a new temperature at which a desired
action starts or stops.
AMBIENT TEMPERATURE
The actual temperature of the room.
AMBIENT HUMIDITY
The actual humidity level of the room.
MINIMUM FAN SPEED
The desired minimum speed for variable speed fans.
RAMPING
An automatic daily reduction in the main set point and all
temperature settings relative to this.
DIFFERENTIAL
ON/OFF (relay).
Range of temperature where two
conditions are possible. The output depends on whether
the temperature was increasing or decreasing when it
enters that range.
VARIABLE.
(Bandwidth) Temperature range where a
variable fan speed fan accelerates, as the temperature
increase. Minimum value at relative set point and 100% at
relative set point + Bandwidth.
DRIP COOL
A device used to cool down livestock.