Page 32
SVIM-1
LE
TROUBLESHOOTING
SYMPTOMS
CAUSES and SOLUTIONS
Display is blank
−
Verify that the line voltage selector switch is
properly set.
−
Check if fuse F3 is blown.
−
Verify that the 10 pin flat cable between the
main board and the faceplate board is
connected.
Open or close
lights go ON but
motor isn’t working
−
The actuator is at its end (open or closed).
−
Fuse F1 is blown. Replace with fuse of the
same type.
−
The actuator’s motor thermal protection is
OPEN.
−
Possible wiring problem.
−
The actuator is defective.
−
The SVIM-1LE has never been calibrated.
The air inlet does
not go to the same
position as
indicated by the
LED
−
The actuator’s motor is connected
backwards, exchange the OPEN and
CLOSE wires of the right hand side (refer to
figure 2).
Err1 on display
−
The curtain is jammed.
−
SVIM-1LE’s calibration is lost.
−
Fuse F1 is blown.
−
Possible wiring problem.
−
The actuator’s motor thermal protection is
OPEN.
Err2 on display
−
Potentiometer is hooked up backwards or
OPEN and CLOSE wires are inverted.
www.monitrol.com
Summary of Contents for SVIM-1LE
Page 1: ...SVIM 1LE User s Manual www monitrol com ...
Page 11: ...Page 11 Fig 2 SVIM 1LE Wiring Diagram CHAPTER 1 INSTALLATION www monitrol com ...
Page 18: ...Page 18 SVIM 1LE www monitrol com ...
Page 19: ...Page 19 CHAPTER 3 USER S GUIDE www monitrol com ...
Page 30: ...Page 30 SVIM 1LE NOTES www monitrol com ...
Page 31: ...Page 31 APPENDIX APPENDIX www monitrol com ...
Page 36: ...MAV SVIM 1LE VER 04 01 July 17 2001 Chip 110e www monitrol com ...