Page 6
SVIM-1
LE
allows to be aware of the system general status and
error messages, if it happens.
Security
The SVIM-1
LE
has several security features. In case it
loses communication with the master control, the SVIM-
1
LE
is able to operate autonomously the air inlet by
using his own temperature probe or by positioning itself
to a preprogrammed position.
The SVIM-1
LE
is also able to detect problems
associated with irregular feedback from a problematic
potentiometer. If it happens the SVIM-1
LE
switches to
time mode, thus allowing normal operation until the
problem is solved.
The time mode feature offers a curtain re-positioning
function. This feature will ensure dependable long term
actuator precision even in the absence of a feedback
potentiometer.
Temperature Probe
The SVIM-1
LE
temperature probe can be installed in
two different ways:
•
Inside probe: With inside temperature probe the
SVIM-1
LE
is able to command the air inlet,
according to the room temperature, in case the
master control loses power or fails.
•
When using an IC (intelligent control) in conjunction
with the SVIM always use the inside probe
configuration (use only the Inside probe option).
•
Outside probe: For applications without feedback
potentiometer, the outside probe is used to ensure
that the air inlet re-positioning will not be done if the
outside temperature exceed a certain temperature
limit.
www.monitrol.com
Summary of Contents for SVIM-1LE
Page 1: ...SVIM 1LE User s Manual www monitrol com ...
Page 11: ...Page 11 Fig 2 SVIM 1LE Wiring Diagram CHAPTER 1 INSTALLATION www monitrol com ...
Page 18: ...Page 18 SVIM 1LE www monitrol com ...
Page 19: ...Page 19 CHAPTER 3 USER S GUIDE www monitrol com ...
Page 30: ...Page 30 SVIM 1LE NOTES www monitrol com ...
Page 31: ...Page 31 APPENDIX APPENDIX www monitrol com ...
Page 36: ...MAV SVIM 1LE VER 04 01 July 17 2001 Chip 110e www monitrol com ...