18
51
Prism
0 - 255
0
Controls Prism mechanism with following values.
0 - 5
→
Open
6 - 10
→
Index
11 - 15
→
Rotate Normal
16 - 20
→
Rotate with Mega Stepping
21 - 255
→
Reserved Values
Prism
Index/Rot
0 - 65535
32767
16-bit control of prism rotation and index.
52
High Byte
53
Low Byte
0 - 126
→
Rotate Fast to Slow <<<
127 - 128
→
Rotation STOP
129 - 255
→
Rotate Slow to Fast >>>
54
Frost
0 - 255
0
Insert control of frost mechanism with the following values.
0 - 50
→
Open - No Frost or Diffusion
51 - 100
→
Insert Light Diffusion
101 - 150
→
Insert Heavy Frost
151 - 200
→
Insert both Light Diffusion and Heavy Frost
DMX
Channel
Parameter
Range DMX Defaults Description
55
Strobe
0 - 255
0
Controls Strobe functionality.
0 - 3
→
Open
4 - 6
→
Closed
7 - 32
→
Normal Strobe - Slow to Fast
33 - 58
→
Random Strobe - Slow to Fast
59 - 84
→
Random Sync - Slow to Fast
85 - 110
→
Pulse > - Slow to Fast
111 - 136
→
Pulse > Random - Slow to Fast
137 - 162
→
Pulse > Random Sync - Slow to Fast
163 - 188
→
Pulse < - Slow to Fast
189 - 214
→
Pulse < Random - Slow to Fast
215 - 240
→
Pulse < Random Sync - Slow to Fast
56
Focus Timing
0 - 255
255
Adjustment of fixture timing to control Pan/Tilt mechanisms.
- See Timing Channel Chart in User Manual
57
Optics
Timing
0 - 255
255
Adjustment of fixture timing to control lensing mechanisms.
- See Timing Channel Chart in User Manual
58
Color Timing
0 - 255
255
Adjustment of fixture timing to control color mechanisms.
- See Timing Channel Chart in User Manual