12
AR80
= 516 mm
AR100
= 554mm
AR80
= 233 mm
AR100
= 297 mm
Adjustment of bowl centering and bowl fixing
Adjusting diameter
Measuring of bowl height
Adjustment of bowl centering:
First find the present bowl centering: mount the beater
and the bowl, then raise the bowl arms up to normal
working position. With your hand turn the beater, and then
measure the distance between beater and bowl edge. By
removing the rear covering, the bowl arm guide plate is
now accessible (E). Loosen the screws (D)
(Fig. 6b)
and
move the bowl arm guide plate in the required direction.
Again turn the beater and measure the distance between
beater and bowl. When the bowl has been centred, fasten
the bowl arm guide plate in the new position and screw
on the rear covering.
Adjustment of bowl fixing:
The bowl arms must be raised to normal working posi-
tion. The adjusting diameter (Y) shall be measured inside
between the bowl arms
(Fig. 6a)
:
Adjusting diameter
(Y)
:
In case the bowl fastening is too loose, remove the lock
ring (B) and draw the bearing (A) from the shaft (C). The
bearing should be turned 180º and be mounted on the
shaft again. It might be necessary to turn both bearings.
At last check the bowl centering and if necessary, adjust.
Measuring of bowl height:
The distance (X) is measured from the bottom side of the
bayonet hole to the surface on the bowl arms on which
the bowl rests
(Fig. 7a)
. The bowl arms must be lifted to
normal working position.
Bowl height (X):
Fig. 6b
Fig. 6a
Fig. 7a