background image

13

C

all

 

uP

 

an

 

error

 

loG

 

of

 

the

 

laSt

 10 

dISConneCtIonS

:

The last 10 disconnections due to errors resulting in code 

 can be read on the mixer display:

• 

Press the emergency stop

• 

Press 

 and 

 to browse the log

• 

The diodes on the speed indicator light up. The age of the error is indicated by the diode that illuminates:

The first diode lights up – the last (most recent) error code is displayed

The second diode lights up – the second-last error code is displayed

The third diode lights up – the third-last error code is displayed, etc. 

e

rror

 

CodeS

 

dISPlayed

 

In

 

the

 

error

 

loG

:

Display

on the 

mixer

Reason for error

User

Engineer

Fault correction

Frequency 

transformer 

display

Error description

1

Error in frequency transformer

Call the engineer

UU

DC bus undervoltage

2

Error in frequency transformer

Call the engineer

OU

DC bus overvoltage

3

Overloading of the frequency 

transformer

Reduce the quan-

tity in the bowl

OI.AC

Overcurrent at drive output

4

Overloading of the frequency 

transformer

Reduce the quan-

tity in the bowl

OI.br

Braking IGBT transistor overcurrent

6

1 phase of supply voltage missing 

 

Call the engineer

ph.AC

Loss of a motor phase with brake enabled

7

??

OSP

Over speed

19

Overloading of the frequency 

transformer

Reduce the quan-

tity in the bowl

it.br

Braking resistor overload I x t

20

Overloading of the motor

Reduce the quan-

tity in the bowl

it.AC

Motor overload I x t

21

Overloading of the frequency 

transformer

Reduce the quan-

tity in the bowl

Oht1

IGBT overheating detected by internal sensor

22

Overloading of the frequency 

transformer

Reduce the quan-

tity in the bowl

Oht2

Internal braking resistor overheating detected by 

thermal sensor

24

Overloading of the motor

Reduce the quan-

tity in the bowl

th

Motor thermal sensor has tripped

26

Error in frequency transformer

Call the engineer

O.Ld1

Overload on the +24V power supply or digital

27

Error in frequency transformer

Call the engineer

CL1

Loss of the current reference on analog input 

ADI1

28

Error in frequency transformer

Call the engineer

CL2

Loss of the current reference on analog input 

ADI2

29

Error in frequency transformer

Call the engineer

CL3

Loss of the current reference on analog input 

ADIO3

30

Connection broken between panel 

and frequency transformer

Call the engineer

SCL

Loss of serial link communication

31

Error in frequency transformer

Call the engineer

EEF

EEPROM trip or transfer problem with XPress-

Key (drive and key version different)

33

Error in motor

Call the engineer

rS

Trip during measurement of the stator resistance

34

Error in frequency transformer

Call the engineer

Fbus

Disconnection of the fieldbus during operation or 

error detected by the bus option

35

Connection broken from saftey cir-

cuit to frequency transformer

Call the engineer

Secd

Secure disable input trip

36

Error in voltage supply to the mixer

Call the engineer

Enc1

Loss of channel U

37

Error in voltage supply to the mixer

Call the engineer

Enc2

Loss of channel V

38

Error in voltage supply to the mixer

Call the engineer

Enc3

Loss of channel W

Summary of Contents for ERGO60

Page 1: ...SPARE PART AND OPERATION MANUAL FOOD MIXER Model ERGO60 ERGO100 ERGO150 012016...

Page 2: ...the mixer is running Do not wear loose clothing or rings while operating the mixer Stop the mixer and lower the bowl before adding ingredients scraping the bowl removing the agitator or removing the p...

Page 3: ...ies LIMITATIONS OF LIABILITY In the event of warranty claim or otherwise the sole obligation of Varimixer shall be the repair and or replacement at the option of Varimixer of the appliance or componen...

Page 4: ...ed by a qualified electrician Of functional and safety reasons the machine must be connected to earth Contents The mixer must be bolted securely to the floor Load per leg not to exceed Voltage at the...

Page 5: ...lift the bowl the rest of the way VL 4 control panel with Remix function See page 7 for an explana tion of the panel Emergency stop Magnetic sensor which is activated by the screen when the screen is...

Page 6: ...terna tively use the beater and the whip Maintenance and lubrication See lubrication overview on page 22 Cleaning The mixer should be cleaned daily or after use Press the emergency stop before wiping...

Page 7: ...sible to store the entire recipe under a program number There are 20 program numbers 1 2 3 4 11 12 13 14 21 22 23 24 31 32 33 34 41 42 43 44 A program cannot be deleted but can be replaced The program...

Page 8: ...e is power connection to the mixer and the bowl is not in its top position The bowl can be raised by activating the fields and simultaneously diodes in the fields are flashing The mixer cannot be star...

Page 9: ...pressing The mixer can be stopped by activating the field By activating the field the bowl is automatically lowered when the mixer stops The field has been activated and the mixer is ready The time ca...

Page 10: ...an operation time for the mixer can be chosen by adjusting the time on and If the field is activated for longer time the speed is increased reduced quicker Minutes and seconds are shown in the text f...

Page 11: ...may be necessary to lower the bowl in order to empty it Release the emergency stop to connect the power to the mixer Lower the bowl and empty it Now the mixer can be used as normal again How to bring...

Page 12: ...ack into the bowl arms the inductive sensor will then be acti vated and you can lift the bowl If contact between the sensor and bowl is interrupted again the error code will appear in the display It i...

Page 13: ...nsformer Reduce the quan tity in the bowl Oht1 IGBT overheating detected by internal sensor 22 Overloading of the frequency transformer Reduce the quan tity in the bowl Oht2 Internal braking resistor...

Page 14: ...rews D and move the bowl arm guide plate in the required direction Again turn the beater and measure the distance between beater and bowl When the bowl has been centred fasten the bowl arm guide plate...

Page 15: ...ght bowl arm resp is shown First find the bowl centering e g by mounting bowl and beater in the mixer and turn the beater round with your hand and measure the distance from the beater to the edge of t...

Page 16: ...16 Electrical components...

Page 17: ...17 Safety circuit...

Page 18: ...rev Project rev Rev 8 Appr init date Const project page Drawing no Subject name Project title File name Page title Main power 1 5 27 10 2015 27 10 2015 2 CE Ergo 60 VL 4 Ergo 100 VL 4 Ergo 140 VL 4 E...

Page 19: ...12 23 24 L 1 9 L 1 9 BU VT K1 J8 J8 J1 J1 J1 J1 J1 J1 J1 J1 J2 J2 J2 J2 J2 J2 J2 J2 PE 1 9 R2 A S WODSCHOW CO Kirkebjerg S park 6 DK 2605 Broenby www bearvarimixer dk Page Previous page Next page Numb...

Page 20: ...e section Fine tuning the reed contacts and CE microswitch The lifting actuator has 3 proximity detectors reed contacts that check the position of the bowl Replacing the Reed contacts Remove the incor...

Page 21: ...e top position of the bowl and the distance Y corresponds to the bottom position of the bowl The distances are measured from the underside of the bayo net shaft to the surface of the bowl arms on whic...

Page 22: ...om Mobil The gear of the actuator is lubricated for life and does not need to be serviced The spindle and the spindle nut in the actual actuator Fig 6a are not lubricat ed for life and therefore need...

Page 23: ...23...

Page 24: ...24...

Reviews: