14
The bearing (A) has two diameters. As standard the mixer
is delivered with the bearings mounted so that the largest
dia meter points away from the bowl arms, which means
the tightest bowl clamping.
a
djuStment
of
bowl
CenterInG
erGo60
and
erGo100:
First find the present bowl centering: mount the beater and
the bowl, then raise the bowl arms up to normal working posi-
tion. With your hand turn the beater, and then measure the
distance between beater and bowl edge. By removing the
rear covering the bowl arm guide plate is now accessible
(E)
.
Loosen the screws
(D)
and move the bowl arm guide plate in
the required direction. Again turn the beater and measure the
distance between beater and bowl. When the bowl has been
centred, fasten the bowl arm guide plate in the new position
and screw on the rear covering.
a
djuStment
of
bowl
fIxInG
erGo60
and
erGo100:
The bowl arms must be raised to normal working position.
The adjusting diameter
(Y)
shall be measured inside between
the bowl arms
:
In case the bowl fastening is too tight, remove the lock ring
(B)
and draw the bearing
(A)
from the shaft
(C)
. The bearing
should be turned 180
o
and be mounted on the shaft again. It
might be necessary to turn both bearings. At last check the
bowl centering and if necessary, adjust.
AE60 = 17 47/64”
Adjusting diameter
(Y)
:
AE100 = 21 13/16”
Summary of Contents for ERGO60