11

Part

Action

Frequency

Note

Safety guard

Check the safety of the safety guard: 

Does the tool stop rotating, when 

the safety guard is not positioned 

correctly?

Regularly

 

If the tool does not imme-

diately stop rotating when the 

safety guard is not positioned 

correctly, the machine must 

not be used.

Call the engineer

Emergency stop

Test the emergency stop: Does the 

tool stop rotating when the emergen-

cy stop is activated

Regularly

 

If the tool does not imme-

diately stop rotating on activa-

tion of the emergency stop, the 

machine must not be used.

Call the engineer

Attachment drive

The rubber plug for covering the 

opening of the attachment drive 

should be on the machine and be 

intact.

Daily

The rubber plug must cover 

the opening on the attachment 

drive when the latter is not in 

use.

Cleaning

Follow the instructions in the section 

“Cleaning”

Follow the instructions 

in the section “Clea-

ning”

Systematic maintenance:

Local 50/60 Hz supply.

Name plate

Power supply:

phases x voltage

With 

neutral

Earth

Voltage Phases

Use

neutral

Use

earth

Notes

1 x 220-240V

Neutral

yes

230V

1

yes

yes

Note that the machine must not be 

connected without an earth, as this may 

compromise the action of the EMC filter 

by removing the discharge to the ground, 

and may be dangerous for the user.

For functional and safety rea-

sons, the machine must be 

connected to the earth.

2 or 3 x 220-240V

-

yes

230V

2

-

yes

2 or 3 x 380-415V

Neutral

yes

230V

1

yes

yes

2 or 3 x 380-480V

-

yes

380-480V

2

-

yes

Example electrical connections:

Summary of Contents for KODIAK10

Page 1: ...Varimixer A S Kirkebjerg S park 6 DK 2605 Br ndby Denmark P 45 4344 2288 E info varimixer com www varimixer com KODIAK KODIAK10 EN DRN 20010 1602 Original user manual 2021 04 22 Operating Instructions...

Page 2: ...The guarantee does not cover damage caused by misuse overloading or the user s failure to comply with the maintenance instructions Unpacking The machine should be unpacked and the packaging disposed o...

Page 3: ...sitioned uppermost on the back of the machine The electrical installation circuit must be secured by a Residual Current Device RCD type A SI The mixer must be earthed Failure to do so may cause Risk o...

Page 4: ...y No access to rotating tools The spread of flour dust is inhibited Equipped with emergency stop The tool stops rotating in less than 4 seconds also for normal shut down and stop via safety guard Clea...

Page 5: ...designed for Kodiak may be used Keep hands out of the bowl while the machine is running can cause severe injury Unless the change is recommended by the manufacturer modifying the machine is prohibite...

Page 6: ...afety guard Mixer head Adjustable legs see page 3 for adjustment Components of the machine When lifted the bowl should be fixed underneath the bowl fitting The bowl must be pushed all the way into the...

Page 7: ...nd intuitive with large push buttons The panel is easy to clean with a damp cloth There is a built in timer function with a display which can also be used to show the number of operating hours Bowl Th...

Page 8: ...ok whip beater scraper with standard blade Optional accessories Scraper blade for high temperature products PTFE Tool rack Equipment Correct use of tools Recommended uses of tool The whip should not b...

Page 9: ...onds in the timer field between and Running times of up to 90 minutes are available When the mixer is running the running time will not be reset if is pressed once press once more and it will be reset...

Page 10: ...ee bearings and should therefore not be lubricated Cleaning The machine may only be cleaned by trained staff and must be over 14 years of age Before any cleaning unplug the machine to prevent electric...

Page 11: ...should be on the machine and be intact Daily The rubber plug must cover the opening on the attachment drive when the latter is not in use Cleaning Follow the instructions in the section Cleaning Follo...

Page 12: ...quency converter Solution Call the engineer Thermal sensor in the frequency converter has cut out Solution The error will disappear when the temperature has dropped to an acceptable level Intermittent...

Page 13: ...total running time of 21 232 min Data set 4 States the number of times the machine has been disconnected from the power supply plug pulled out of the machine powercut switched off and restarted displa...

Page 14: ...Page Project rev Case no Project title CR10 VL1C 200 230V N PE 11 PCSCHEMATIC Automation 1 2 3 4 5 6 7 8 F1 Fuse 10A 14 Circuit diagram 110 230V R1 Ground choker 100 120V only...

Page 15: ...Menger Declaramos que el producto batidora er i overensstemmelse med relevante bestemmelser i Maskindirektivet Direktiv 2006 42 EC is in conformity with the relevant provisions of the Machinery Direc...

Page 16: ...Varimixer A S Kirkebjerg S park 6 DK 2605 Br ndby P 45 4344 2288 E info varimixer com www varimixer com...

Reviews: