Description
Components
Fig. 1
Allocation: Definition
The temperature on the bottom of the pan is regulated via a 'network' of thermocouples.
Model 112 / 112T, 6 thermocouples
Model 211 / 311,
8 thermocouples
Model 112L
12 thermocouples
Each of these must be assigned to a heating zone. This assignment is called the allocation.
Allocation is an automatic process available in service mode, which takes about 5 minutes
(e.g. model 112). Each heating zone is powered for a predefined time, after which the software looks
for the thermocouple that reacted to the change in temperature. The thermocouple it finds is then
associated with the heating zone.
When should an allocation be carried out?
This operation is not necessary after each intervention. Here are the situations where it must be
carried out:
Exchange of
●
The main board A2 (42.00.080V)
●
The I/O board A4 (42.00.159F)
●
More than one thermocouple
●
The SD card (42.00.128)
●
More than one heater
●
More than one SSR
In all cases if:
●
More than one thermocouple has been
disconnected
●
The cook complains of irregularity in cooking
IX.10
v03 • July-2016 • Hen
Heating system module
V1 - V6
R1 - R12
Line
Units
Serial number (starting from)
Sw
Revision
VCCM
VCCWE
All
ExxXH1009xxxxxxx
?
?
X106.1
X108.1
X107.1
X106.2
X108.2
X107.2
X106.3
X107.3
B4 - B17
A4
1
Summary of Contents for WHITEFICIENCY Series
Page 2: ...v03 July 2016 Hen I 02...
Page 6: ...Contents GB v03 July 2016 Hen...
Page 12: ...Preamble GB v03 July 2016 Hen...
Page 22: ...User mode module GB v03 July 2016 Hen...
Page 24: ...IV 02 v03 July 2016 Hen Service Mode Module I n t e n t i o n a l l y l e f t b l a n k...
Page 44: ...Service mode module GB v03 July 2016 Hen...
Page 46: ...v03 July 2016 Hen V 02 Communication Module...
Page 64: ...Communication Module GB v03 July 2016 Hen...
Page 82: ...Control Module GB v03 July 2016 Hen...
Page 96: ...Power supply module GB v03 July 2016 Hen...
Page 98: ...VIII 02 v03 July 2016 Hen Hydraulic circuit Module I n t e n t i o n a l l y l e f t b l a n k...
Page 106: ...Hydraulic circuit module GB v03 July 2016 Hen...
Page 128: ...Heating Module GB v03 July 2016 Hen...
Page 170: ...Motorisation Module GB v03 July 2016 Hen...
Page 186: ...Pressure Module GB v03 July 2016 Hen...
Page 194: ...Cooking mode module GB v03 July 2016 Hen...
Page 206: ...Service message module GB v03 July 2016 Hen...
Page 207: ...v03 July 2016 Hen Line Units Serial number starting from Sw Revision VCCM VCCWE...
Page 208: ...Technical Manual VarioCooking Center EN v03 July 2016 Hen...