Boiling mode
●
Temperature: 30°C - Boiling temperature
●
Additional function: PowerBoost
Step
Operation
Note / Safety
A
Preconditions
●
Lid must be detected in the up position
●
Lid must be unlocked: (Pressure units)
●
Pan must be detected in the down position
The heating is turned of
f if the angle of the
pan is > 12°
Pan valve closes* if detected open
B
Regulation
Regulation via:
Pan thermocouple (L: B1 / R: B2)
or
core probe (L: B12 / R: B13)
The choice between the core probe and the pan thermocouple is made based on the highest temperature.
C
Regulation / lid closed
If the lid is no longer detected in the up position, then the maximum temperature = [T° boiling -3°C]. V
ia pan thermocouple (L: B1 / R: B2)
or
core probe (L: B12 / R: B13) Same conditions for selection as in
step B.
The heating is turned of
f if the angle of the
pan is > 12°
D
Complementary PowerBoost function
Regulation of heating via heating thermocouples.
112G: B4 > B6 / 1
12D: B7 > B9
21
1/31
1: B4 > B1
1
For
the
pressure
cooker
mode,
you
will
find
a
detailed
description
of
the
process
in
the
pressure
module.
* Only on devices equipped with a motorised pan valve.
XII.03
v03 • July-2016 • Hen
Cooking mode module
Line
Units
Serial number (starting from)
Sw
Revision
VCCM
VCCWE
112P, 211P, 311P
ExxXH1009xxxxxxx
01-01-00
Summary of Contents for WHITEFICIENCY Series
Page 2: ...v03 July 2016 Hen I 02...
Page 6: ...Contents GB v03 July 2016 Hen...
Page 12: ...Preamble GB v03 July 2016 Hen...
Page 22: ...User mode module GB v03 July 2016 Hen...
Page 24: ...IV 02 v03 July 2016 Hen Service Mode Module I n t e n t i o n a l l y l e f t b l a n k...
Page 44: ...Service mode module GB v03 July 2016 Hen...
Page 46: ...v03 July 2016 Hen V 02 Communication Module...
Page 64: ...Communication Module GB v03 July 2016 Hen...
Page 82: ...Control Module GB v03 July 2016 Hen...
Page 96: ...Power supply module GB v03 July 2016 Hen...
Page 98: ...VIII 02 v03 July 2016 Hen Hydraulic circuit Module I n t e n t i o n a l l y l e f t b l a n k...
Page 106: ...Hydraulic circuit module GB v03 July 2016 Hen...
Page 128: ...Heating Module GB v03 July 2016 Hen...
Page 170: ...Motorisation Module GB v03 July 2016 Hen...
Page 186: ...Pressure Module GB v03 July 2016 Hen...
Page 194: ...Cooking mode module GB v03 July 2016 Hen...
Page 206: ...Service message module GB v03 July 2016 Hen...
Page 207: ...v03 July 2016 Hen Line Units Serial number starting from Sw Revision VCCM VCCWE...
Page 208: ...Technical Manual VarioCooking Center EN v03 July 2016 Hen...