Description of the Service Mode
Diagnosis, sensors
Contacts on the left side
Probe
Use
Unit
Cover up
Limit switch S10, cover
up
112, 112T; 112L
Cover
down
Limit switch S11, cover
down
112P
Cover
unlocked
Limit switch S6, cover
unlocked
112P, 211P,
311P
Cover
locked
Limit switch S7, cover
locked
112P, 211P,
311P
Pan
valve
Microswitch S8,
position pan valve
All
Pan
down
Limit switch S25,
pan down
112T
Pan up
Limit switch S27,
pan up
112T
Left potentiometer
Probe
Use
Unit
Angle of
pan
Potentiometer PT1
112, 112T,
112L, 211, 311
Cover
angle
Potentiometer PT2
211, 311
Contacts right side
Probe
Use
Unit
Cover up
Limit switch S12, cover
up
112, 112T, 112L
Cover
down
Limit switch S13, cover
down
112P
Cover
unlocked
Limit switch S18, cover
unlocked
112P,
Cover
locked
Limit switch S19, cover
locked
112P
Pan
valve
Microswitch S20, posi-
tion pan valve
112, 112T, 112L
Pan
down
Limit switch S26,
pan down
112T
Pan up
Limit switch S28,
pan up
112T
Right potentiometer
Probe
Use
Unit
Angle of
pan
Potentiometer PT2
112, 112T, 112L
Columns displayed
Column
Explanation
Details
Code
Name of the sensor concerned
●
S for microswitch, limit switch
●
Y for solenoid valves
●
PT for potentiometers
●
P for pressure sensors
Status
Sensor status
●
0 for inactive
●
1 for active
Angle
Angular value calculated based on
the digital value (gross value)
●
Value calculated in relation to the last point
of reference
Gross value
Or digital value. This is the gross
value of the potentiometer
(without angle conversion)
IV.08
v03 • July-2016 • Hen
Service Mode Module
Line
Units
Serial number (starting from)
Sw
Revision
VCCM
VCCWE
All
ExxXH1009xxxxxxx
01-00-08
Summary of Contents for WHITEFICIENCY Series
Page 2: ...v03 July 2016 Hen I 02...
Page 6: ...Contents GB v03 July 2016 Hen...
Page 12: ...Preamble GB v03 July 2016 Hen...
Page 22: ...User mode module GB v03 July 2016 Hen...
Page 24: ...IV 02 v03 July 2016 Hen Service Mode Module I n t e n t i o n a l l y l e f t b l a n k...
Page 44: ...Service mode module GB v03 July 2016 Hen...
Page 46: ...v03 July 2016 Hen V 02 Communication Module...
Page 64: ...Communication Module GB v03 July 2016 Hen...
Page 82: ...Control Module GB v03 July 2016 Hen...
Page 96: ...Power supply module GB v03 July 2016 Hen...
Page 98: ...VIII 02 v03 July 2016 Hen Hydraulic circuit Module I n t e n t i o n a l l y l e f t b l a n k...
Page 106: ...Hydraulic circuit module GB v03 July 2016 Hen...
Page 128: ...Heating Module GB v03 July 2016 Hen...
Page 170: ...Motorisation Module GB v03 July 2016 Hen...
Page 186: ...Pressure Module GB v03 July 2016 Hen...
Page 194: ...Cooking mode module GB v03 July 2016 Hen...
Page 206: ...Service message module GB v03 July 2016 Hen...
Page 207: ...v03 July 2016 Hen Line Units Serial number starting from Sw Revision VCCM VCCWE...
Page 208: ...Technical Manual VarioCooking Center EN v03 July 2016 Hen...