Hydraulic circuit
Components, Safety
Water filling emergency stop Fig. B
Press the function selector, the filling is
immediately stopped.
Variodose
Fig. C
The filling of the pan is measured using an ana
-
logue meter called a VarioDose.
The VarioDose delivers a pulse train when it is
crossed by a stream of water.
The number of pulses issued per litre may vary
depending on the model of the flow meter used.
To be precise the flow must be that recommended
in our installation manual. Outside the specified
tolerances, the output signal of the flow meter
varies.
The number of pulses corresponding to a
unit of water is adjustable in service mode.
●
Service mode > Basic settings > VarioDose
Oil protection
Fig. D
For units manufactured since 10/2013:
The power to the water-fill solenoid valves Y1
and Y3 is protected via a 130°C bimetal.
Filling is impossible if the pan temperature
exceeds 130°C. The client is informed that the
pan is too hot thanks to the pan thermocouple.
v03 • July-2016 • Hen
Hydraulic circuit Module
VIII.03
Line
Units
Serial number (starting from)
Sw
Revision
VCCM
VCCWE
All
ExxXH1009xxxxxxx
TOUCH + TFT
+ A1 (MMi)
Y1 - Y4
F25 - F26
A2 (Main Board)
VarioDose
A
C
B
D
Y1 - Y4
F25 - F26
Summary of Contents for WHITEFICIENCY Series
Page 2: ...v03 July 2016 Hen I 02...
Page 6: ...Contents GB v03 July 2016 Hen...
Page 12: ...Preamble GB v03 July 2016 Hen...
Page 22: ...User mode module GB v03 July 2016 Hen...
Page 24: ...IV 02 v03 July 2016 Hen Service Mode Module I n t e n t i o n a l l y l e f t b l a n k...
Page 44: ...Service mode module GB v03 July 2016 Hen...
Page 46: ...v03 July 2016 Hen V 02 Communication Module...
Page 64: ...Communication Module GB v03 July 2016 Hen...
Page 82: ...Control Module GB v03 July 2016 Hen...
Page 96: ...Power supply module GB v03 July 2016 Hen...
Page 98: ...VIII 02 v03 July 2016 Hen Hydraulic circuit Module I n t e n t i o n a l l y l e f t b l a n k...
Page 106: ...Hydraulic circuit module GB v03 July 2016 Hen...
Page 128: ...Heating Module GB v03 July 2016 Hen...
Page 170: ...Motorisation Module GB v03 July 2016 Hen...
Page 186: ...Pressure Module GB v03 July 2016 Hen...
Page 194: ...Cooking mode module GB v03 July 2016 Hen...
Page 206: ...Service message module GB v03 July 2016 Hen...
Page 207: ...v03 July 2016 Hen Line Units Serial number starting from Sw Revision VCCM VCCWE...
Page 208: ...Technical Manual VarioCooking Center EN v03 July 2016 Hen...