Calibration
Error codes
Error code
Explanation
Troubleshooting
Error-31
The offset temperature of the
left pan (B1) is not within the
tolerances [-3°C + 7°C]
●Altitude setting?
●
Check the thermocouple for good contact
with pan bottom
●
For pressure units only:
Check for correct function of the pressure
sensor? Pressure circuit blocked?
●
Thermocouple or corresponding PCB mal-
function
Error-30
At least one point of the right
core probe is outside tolerance
[-3°C; +3°C]
●Enough water present?
●Core probe fully submerged?
●Altitude setting?
●
For pressure units only:
Check for correct function of the pressure
sensor? Pressure circuit blocked?
●
Thermocouple or corresponding PCB mal-
function
Error-29
The offset temperature of the
right pan (B2) is not within the
tolerances [-3°C + 7°C]
●Altitude setting?
●
Check the thermocouple for good contact
with pan bottom
●
For pressure units only:
Check for correct function of the pressure
sensor? Pressure circuit blocked?
●
Thermocouple or corresponding PCB mal-
function
Error-28
Reading problem on left core
probe (B12.1 > B12.6)
●
The temperature values read are too in-
consistent or have too great a variation
The reading of a single defective point out of
6 is sufficient to generate the error.
●
Poor contact from the thermocouple to the
board
●
Thermocouple malfunction
●
PCB malfunction
Error-27
Reading problem on the right
core probe (B13.1 > B13.6)
Error-26
Reading problem on left pan
(B1)
Error-25
Reading problem on right pan
(B2)
IX.21
v03 • July-2016 • Hen
Heating system module
Line
Units
Serial number (starting from)
Sw
Revision
VCCM
VCCWE
All
ExxXH1009xxxxxxx
Summary of Contents for WHITEFICIENCY Series
Page 2: ...v03 July 2016 Hen I 02...
Page 6: ...Contents GB v03 July 2016 Hen...
Page 12: ...Preamble GB v03 July 2016 Hen...
Page 22: ...User mode module GB v03 July 2016 Hen...
Page 24: ...IV 02 v03 July 2016 Hen Service Mode Module I n t e n t i o n a l l y l e f t b l a n k...
Page 44: ...Service mode module GB v03 July 2016 Hen...
Page 46: ...v03 July 2016 Hen V 02 Communication Module...
Page 64: ...Communication Module GB v03 July 2016 Hen...
Page 82: ...Control Module GB v03 July 2016 Hen...
Page 96: ...Power supply module GB v03 July 2016 Hen...
Page 98: ...VIII 02 v03 July 2016 Hen Hydraulic circuit Module I n t e n t i o n a l l y l e f t b l a n k...
Page 106: ...Hydraulic circuit module GB v03 July 2016 Hen...
Page 128: ...Heating Module GB v03 July 2016 Hen...
Page 170: ...Motorisation Module GB v03 July 2016 Hen...
Page 186: ...Pressure Module GB v03 July 2016 Hen...
Page 194: ...Cooking mode module GB v03 July 2016 Hen...
Page 206: ...Service message module GB v03 July 2016 Hen...
Page 207: ...v03 July 2016 Hen Line Units Serial number starting from Sw Revision VCCM VCCWE...
Page 208: ...Technical Manual VarioCooking Center EN v03 July 2016 Hen...