Series 200
260 to 243
Num. Com
-
ponent
Conditions
Diagnosis
260
P1
The pressure measured
by the sensor is lower than
30 mbar
●
Check the connection from the sensor to the correspond-
ing board.
●
check the power supply to the board (18 VAC for A2,
11.5VAC for A4)
●
Check that another component connected to the board is
not affecting the measurement from the sensor. Proceed by
a process of elimination by unplugging one after the other,
including the actuator potentiometers.
261
P2
262
P1
DANGER OF BURNS!
HANDLE WITH CARE!
During the pressure mode
the temperature rises but
not the pressure!
●
Turn off the unit in order to let it depressurise
●
Before unlocking make sure that the pan is pressure-free
●
Check the cleanliness of the pressure-
measuring circuit.
●
Clean the circuit.
●
check the functioning of the pressure sensor P1 / P2 and
the pressure switches F7/F11, F12/F13
●
If all this is checked and ok, then recalibrate the unit. These
are the essential conditions: Enough water in the pan, insert
the core probe, the pan must be lined (no lining panel miss-
ing)
263
P2
XIII.09
v03 • July-2016 • Hen
Service message module
Line
Units
Serial number (starting from)
Sw
Revision
VCCM
VCCWE
All
ExxXH1009xxxxxxx
01-00-08
Summary of Contents for WHITEFICIENCY Series
Page 2: ...v03 July 2016 Hen I 02...
Page 6: ...Contents GB v03 July 2016 Hen...
Page 12: ...Preamble GB v03 July 2016 Hen...
Page 22: ...User mode module GB v03 July 2016 Hen...
Page 24: ...IV 02 v03 July 2016 Hen Service Mode Module I n t e n t i o n a l l y l e f t b l a n k...
Page 44: ...Service mode module GB v03 July 2016 Hen...
Page 46: ...v03 July 2016 Hen V 02 Communication Module...
Page 64: ...Communication Module GB v03 July 2016 Hen...
Page 82: ...Control Module GB v03 July 2016 Hen...
Page 96: ...Power supply module GB v03 July 2016 Hen...
Page 98: ...VIII 02 v03 July 2016 Hen Hydraulic circuit Module I n t e n t i o n a l l y l e f t b l a n k...
Page 106: ...Hydraulic circuit module GB v03 July 2016 Hen...
Page 128: ...Heating Module GB v03 July 2016 Hen...
Page 170: ...Motorisation Module GB v03 July 2016 Hen...
Page 186: ...Pressure Module GB v03 July 2016 Hen...
Page 194: ...Cooking mode module GB v03 July 2016 Hen...
Page 206: ...Service message module GB v03 July 2016 Hen...
Page 207: ...v03 July 2016 Hen Line Units Serial number starting from Sw Revision VCCM VCCWE...
Page 208: ...Technical Manual VarioCooking Center EN v03 July 2016 Hen...