Operation
41
GB
322891 / 396630
V_01/02/2011
Electrical connection
The device may only be operated under the following conditions:
• The device may only be connected to outlets with protective contacts that have been profes-
sionally installed, grounded and inspected.
• Mains voltage and fuse protection must comply with the technical data.
• When operating in swimming pools, garden ponds and similar places, the device must be
provided with a residual current of not more than 30 mA by means of a residual-current-oper-
ated protective device.
• When operating outdoors, the electrical connections must be splash-proof; they must not lie
in water.
• Extension cords must have sufficient wire cross section; cable drums must be complete
unwound.
Operation
Filling and intake [suction]
1. Unscrew filter housing (6) and remove filter.
2. Fill completely with water.
3. Reinstall filter and screw filter housing and seal back on.
4. If you want to shorten the intake time, fill the suction line as well (only possible with the check
valve).
5. Open pressure line (turn on water spigot or nozzle), so that air can escape during intake.
6. Switch the device on.
7. When water runs out evenly, turn the device off.
Operation
The pump and suction line must be connected and filled.
Note:
The device may only be used for industrial water supply, e. g. from the toilets, wash-
ing machine, etc.
It may not be used for drinking water supply.
Danger!
Mortal danger due to electric shock!
Do not operate the device in wet surroundings!
Attention!
Risk of damage to the device!
The pump should be filled with water after each new connection or in the event of
water loss or air intake. Extended operation without a water refill (unsupervised dry
run) will destroy the pump!
Note:
We recommend installing a check valve between the pump and suction line, so that
the water column remains in the suction line.
We recommend using a suction filter for better suction performance.
Gartenpumpe_322891_396630.book Seite 41 Montag, 7. Februar 2011 8:50 08