22
If you can’t fix the fault yourself, contact your nearest
vendor. Please be aware that any improper repairs
will also invalidate the warranty and additional costs
may be incurred.
Disposal
Disposal of the appliance
Appliances which are labelled with the adja-
cent symbol must not be disposed of in
household waste. You must dispose of such
old electrical and electronic equipment sep-
arately.
– Please check with your local authority about the
possibilities for correct disposal.
Through separate disposal you send old equipment
for recycling or for other forms of re-use. You will
thus help to avoid in some cases that damaging
material gets into the environment.
Disposal of the packaging
The packaging consists of cardboard and
correspondingly marked plastics that can
be recycled.
– Make these materials available for
recycling.
Technical data
Float switch defective?
Contact service partner.
Level probe does not operate?
Ensure there is sufficient liquid present.
Is level probe defective?
Contact service partner.
Motor overheats due to:
• liquid temperature too high?
• blocking by foreign bodies?
Eliminate the cause of the overheating (max.
temperature of liquid
Residual current circuit breaker
(RCCB) triggered?
Activate RCCB. Contact qualified electrician if
RCCB triggers again.
Motor defective?
Contact service partner.
Pump runs but does not
pump.
Suction openings blocked?
Rectify blockage.
Pump draws in air?
Keep the pump at an angle while submerging.
Switch the pump on and off several times in or-
der to expel air.
Pump blocked by foreign bodies?
Clean the pump (
Delivery rate too low.
Delivery height too great?
Comply with maximum delivery height
(
Pressure line diameter too small?
Use pressure line with larger diameter.
Pressure line blocked?
Rectify blockage.
Suction openings blocked?
Clean suction opening.
Pressure line kinked?
Straighten pressure line.
Pressure line leaks?
Seal pressure line, tighten threaded connec-
tions.
Pump runs very loudly.
Pump draws in air?
Ensure there is sufficient liquid present.
Adjust float switch correctly (
Keep the pump at an angle while submerging.
Pump does not switch
off.
Float switch does not reach the bot-
tom position?
Pull out the plug.
Ensure that the float switch can move suffi-
ciently.
Float switch defective?
Contact service partner.
Level probe soiled?
Clean the level probe.
Is level probe defective?
Contact service partner.
Fault/malfunction
Cause
Remedy
Item number
322 904
396 570
Model
V-TP 400
V-TP 600
Rated voltage
230 V ~ /50 Hz
230 V ~ /50 Hz
GB
Tauchpumpe_322904_396570.book Seite 22 Mittwoch, 23. September 2015 11:45 11
Summary of Contents for V-TP 400
Page 3: ...3 1 1 6 4 7 2 5 3 Tauchpumpe_322904_396570 book Seite 3 Mittwoch 23 September 2015 11 45 11...
Page 57: ...57 58 57 58 RU Tauchpumpe_322904_396570 book Seite 57 Mittwoch 23 September 2015 11 45 11...
Page 59: ...59 RU Tauchpumpe_322904_396570 book Seite 59 Mittwoch 23 September 2015 11 45 11...
Page 65: ...65 RU 1 2 24 3 Tauchpumpe_322904_396570 book Seite 65 Mittwoch 23 September 2015 11 45 11...
Page 66: ...66 4 20 13109 97 Tauchpumpe_322904_396570 book Seite 66 Mittwoch 23 September 2015 11 45 11...
Page 69: ...69 Tauchpumpe_322904_396570 book Seite 69 Mittwoch 23 September 2015 11 45 11...