Installation:
●
Connection all cables before connecting the main power supply
●
The assembly adaptor with a M8 grub screw and 1/4 " tripod thread is screwed on
either on upper or bottom side of the camera case. Take care that only delivered screws
are used.
●
Due to high tempertures near camera please take care for proper cooling.
If needed please use the optional cooling device.
Tubes with 6 mm of outer diameter can be mounted to the water cooling. For an
effective cooling the water flow should have a min. amount of approx. 6-8 l/h.
●
At the assembly (mounting) of the camera is to be noted that the camera is set in
correct distance according to used close lens. This distance is to be kept - otherwise a
sharp position adjustment of the object is not guaranteed.
with close up lens
distance to front of camera
+1
45...75 cm
+2
30...45 cm (Standard)
+3
22...30 cm (= com1 and +2)
+4
16...22 cm
●
The camera cable is drag chain suitable. The length may be to maximum 50 m. The
15pin Sub D socket is camera-sided, while on operating panel side is a 15pin Sub D
plug. The pinning is one to one. The copper-shield is connected with the sockets and
plug case. The system can therefore from the camera up to the operating panel connect
to ground/earthing by the yellow/green earthing connection..
Variovision, Pöttinger Straße 23, DE-82041 Oberhaching, www.variovision.tv, info@variovision.tv
9/14
WVS-16
Automatic Ext. Control
Please note:
DIM-Function is only active if the contact on ext. control is closed
From Welding machine