To remove: 

 

Depress the latches in the front of the battery pack to release the battery pack and remove 
it from the tool. 

7.3 

Start switch and self-locking switch 

 

When press start switch, push self-locking switch up, which will make the switch in LOCK-
ON.This guarantees the safety for the user and of the tool. 

 

After the pressure enough, pressing the start switch, then the self-locking switch will 
sprang back down. 

7.4 

LED working light 

When working, the LED light on the base of the tool is on, 
which is good for nightwork. 

7.5 

Accessories 

The supplied accessories perform a variety of functions. 
The tapered adaptor can be used on smaller pinch valves to inflate small items like children’s 
toys, which usually require the user to inflate them by blowing air into them. 
The sport ball needle can be used to inflate any type of sports ball or any other item that 
requires an inflation sport ball needle. 

NOTE: When inflating items of 10 PSI or less, inflate in short bursts and 
check after each burst by feel or with a calibrated measuring device to 
determine accurate pressure. 

7.5.1 

Sport ball needle: 

 

Insert sport ball needle into sports ball valve and inflate. 

 

Remove sport ball needle after inflation. 

NOTE: Pressure required for most sports balls is too low for accurate 
reading on tool gauge. 

7.5.2 

Valve adaptor 

Before inflating a tire with a valve, loosen the locking nut on the valve stem to inflate. Once 
inflation is complete, tighten the locking nut to seal the tire valve. 

 

Loosen the valve locking nut. 

 

Thread the valve adaptor onto the valve stem with the larger open end toward the wheel. 

 

Position the air chuck clamp in the unlock position. 

 

Clamp the end of the air chuck down onto the valve adaptor by pressing air chuck clamp 
down until it locks into place. 

 

After inflation, remove air chuck and tighten locking nut. 

8  USING THE INFLATOR 

 

Install the battery pack. 

 

Position air chuck clamp in the unlock position perpendicular to the air hose. 

 

Place the air chuck on the valve stem. 

 

Push the air chuck down so that the threaded section of the valve stem is inside the air 
chuck. 

 

Clamp the end of the air chuck down onto the valve stem by pressing air chuck clamp 
down until it stops or is parallel with the air hose. 

Summary of Contents for POWERplus POWX1700

Page 1: ...5 5 Service 5 6 ADDITIONAL SAFETY INSTRUCTIONS 5 7 OPERATION 6 7 1 Charging the battery 6 7 2 Connecting and removing the battery 6 7 2 1 To install 6 7 2 2 To remove 7 7 3 Start switch and self locking switch 7 7 4 LED working light 7 7 5 Accessories 7 7 5 1 Sport ball needle 7 7 5 2 Valve adaptor 7 8 USING THE INFLATOR 7 9 CLEANING AND MAINTENANCE 8 9 1 Cleaning 8 9 2 Maintenance 8 10 TECHNICAL ...

Page 2: ...POWX1700 EN Copyright 2020 VARO P a g e 2 www varo com 15 DECLARATION OF CONFORMITY 10 ...

Page 3: ...Battery release button 8 Pressure gauge 9 Air chuck 10 Hose storage area 11 Self locking switch 12 Charger 13 LED light 3 PACKAGE CONTENT LIST Remove all packing materials Remove remaining packaging and transit supports if existing Check the completeness of the packing content Check the appliance the power cord the power plug and all accessories for transportation damages Keep the packaging materi...

Page 4: ...dy is earthed or grounded Do not expose power tools to rain or wet conditions Water entering a power tool will increase the risk of electric shock Do not abuse the cord Never use the cord for carrying pulling or unplugging the power tool Keep cord away from heat oil sharp edges or moving parts Damaged or entangled cords increase the risk of electric shock When operating a power tool outdoors use a...

Page 5: ...ls sharp and clean Properly maintained cutting tools with sharp cutting edges are less likely to stick and are easier to control Use the power tool accessories and tool bits etc in accordance with these instructions and in the manner intended for the particular type of power tool taking into account the working conditions and the work to be performed Use of the power tool for operations different ...

Page 6: ... or replaced by an authorized service center Following this rule will reduce the risk of shock fire or serious injury Inspect tool cords periodically and if damaged have repaired at your nearest Authorized Service Center Constantly stay aware of cord location Following this rule will reduce the risk of electric shock or fire Risk of bursting Carefully monitor objects during inflation To reduce the...

Page 7: ...k after each burst by feel or with a calibrated measuring device to determine accurate pressure 7 5 1 Sport ball needle Insert sport ball needle into sports ball valve and inflate Remove sport ball needle after inflation NOTE Pressure required for most sports balls is too low for accurate reading on tool gauge 7 5 2 Valve adaptor Before inflating a tire with a valve loosen the locking nut on the v...

Page 8: ...are and regular cleaning 10 TECHNICAL DATA POWX1700 Motor voltage 18 V battery Li ion 18V 1500mAh Max Pressure 8 bar Weight including battery 1 1kg Power supply 100 240V 50 60Hz Rated charging voltage 18 V Rated voltage of chargeable battery 18 V Charging time 1 hours Current of charge 1 5 A 11 NOISE Noise emission values measured according to relevant standard K 3 Acoustic pressure level LpA 81 d...

Page 9: ...competent usage e g not following the instructions given in the manual inexpert assembly lightning strike erroneus net voltage This list is not exhaustive Acceptance of claims under warranty can never lead to the prolongation of the warranty period nor commencement of a new warranty period in case of a device replacement Devices or parts which are replaced under the warranty therefore remain the p...

Page 10: ...on of European harmonized standards Any unauthorized modification of the apparatus voids this declaration European Directives including if applicable their amendments up to the date of signature 2011 65 EU 2006 42 EC 2014 30 EC European harmonized standards including if applicable their amendments up to the date of signature EN60745 1 2009 EN55014 1 2006 EN55014 2 2015 Keeper of the Technical Docu...