background image

 

POWXG9417 

EN

 

Copyright © 2015 VARO NV 

P a g e

 | 

5

 

www.varo.com 

Important ! Note! 

Remove the mains plug before all maintenance work. 

 

When the pump is often transported in the course of operation, it should be cleaned out 
with clear water after every use. 

 

All fibrous particles which may have built-up inside the pump housing should be removed 
with a water jet. 

 

Every 3 months the shaft ground and as should be cleaned from mud. 

 

Remove deposits on the floater with clear water. 

8.2 

Cleaning the impeller 

If excessive deposits collect in the pump case you must dismantle the bottom part of the pump 
as follows: 
1. 

Remove the intake cage from the pump case. 

2. 

Clean the impeller with clear water. 

Important! Do not put down or rest the pump on the impeller! 

3. 

Re-assemble in reverse order 

9  TECHNICAL DATA 

 
type 

POWXG9417 

Voltage / frequency 

230V~ 50Hz 

Power input 

750W 

Delivery rate max.. 

13500 l/h 

Delivery height max 

7.5 m

 

Immersion depth max. 

max. 7 m 

Water temperature max. 

35° C 

Hose connection 

5/4" 

Foreign bodies up to 

35 mm 

Switching point high: ON 

16, 20, 24 or, 28cm 

Switching point high: OFF 

ca. 5 cm 

For clean/dirty water: 

Dirty

 

Housing (plastic(P) /   Stainless Steel (SS) ) 

SS 

Water inlet (plastic /   Stainless Steel (SS) ) 

SS 

Weight 

6.81kg 

10 SERVICE DEPARTMENT 

 

Damaged switches must be replaced by our after-sales service department. 

 

If the connecting cable (or mains plug) is damaged, it must be replaced by a special 
connecting cable which is available from our service department. Replacement of the 
connecting cable should only be carried out by our service department (see last page) or 
by a qualified specialist (qualified electrician). 

Summary of Contents for POWERplus POWXG9417

Page 1: ...WARNINGS 2 5 BEFORE START UP NOTE THE FOLLOWING 3 6 INSTALLATION 3 7 SETTING TO WORK 4 7 1 Setting the ON OFF operating point 4 8 CLEANING AND MAINTENANCE 4 8 1 Maintenance guidelines 4 8 2 Cleaning the impeller 5 9 TECHNICAL DATA 5 10 SERVICE DEPARTMENT 5 11 TROUBLESHOOTING 6 12 STORAGE 6 13 WARRANTY 6 14 ENVIRONMENT 7 15 DECLARATION OF CONFORMITY 7 ...

Page 2: ...T LIST Remove all packaging materials Remove remaining packaging and packing inserts if included Check that the package contents are complete Check the appliance the power cord the power plug and all accessories for transportation damage Keep the packaging materials as far as possible until the end of the warranty period Then take it to your local waste disposal system WARNING Packaging materials ...

Page 3: ... from running dry Access on the part of children should also be prevented with appropriate measures Consistency Your submersible pump is designed for the circulation of water with a maximum temperature of 35 C This pump may not be used for other fluids especially motor fuels cleaning fluids and other chemical products 6 INSTALLATION The submersible motor pump is installed as follows In a stationar...

Page 4: ...h the pump off If the sensor is still under water the pump can only be restarted by pulling the mains plug and then plugging it in again reset 2 When the pump is under water loaded and the water level is above the two touch points submerged the electronic switch will start the pump after 5 6 sec When the water level is below the minimum pump level dry the electronic switch will stop the pump 1 Whe...

Page 5: ...ut down or rest the pump on the impeller 3 Re assemble in reverse order 9 TECHNICAL DATA type POWXG9417 Voltage frequency 230V 50Hz Power input 750W Delivery rate max 13500 l h Delivery height max 7 5 m Immersion depth max max 7 m Water temperature max 35 C Hose connection 5 4 Foreign bodies up to 35 mm Switching point high ON 16 20 24 or 28cm Switching point high OFF ca 5 cm For clean dirty water...

Page 6: ...ents or alterations nor the cost of transportation Damage and or defects resulting from inappropriate use also do not fall under the warranty provisions We also disclaim all liability for any bodily injury resulting from inappropriate use of the tool Repairs may only be carried out by an authorised customer service centre for Powerplus tools You can always obtain more information at the number 00 ...

Page 7: ...9 BE2500 Lier BELGIUM declares that product submersible pump trade mark POWERplus model POWXG9417 is in conformity with the essential requirements and other relevant provisions of the applicable European Directives based on the application of European harmonized standards Any unauthorized modification of the apparatus voids this declaration European Directives including if applicable their amendme...