Important ! Note!
Remove the mains plug before all maintenance work.
When the pump is often transported in the course of operation, it should be cleaned out
with clear water after every use.
All fibrous particles which may have built-up inside the pump housing should be removed
with a water jet.
Every 3 months the shaft ground and as should be cleaned from mud.
Remove deposits on the floater with clear water.
8.2
Cleaning the impeller
If excessive deposits collect in the pump case you must dismantle the bottom part of the pump
as follows:
1.
Remove the intake cage from the pump case.
2.
Clean the impeller with clear water.
Important! Do not put down or rest the pump on the impeller!
3.
Re-assemble in reverse order
9 TECHNICAL DATA
type
POWXG9417
Voltage / frequency
230V~ 50Hz
Power input
750W
Delivery rate max..
13500 l/h
Delivery height max
7.5 m
Immersion depth max.
max. 7 m
Water temperature max.
35° C
Hose connection
5/4"
Foreign bodies up to
35 mm
Switching point high: ON
16, 20, 24 or, 28cm
Switching point high: OFF
ca. 5 cm
For clean/dirty water:
Dirty
Housing (plastic(P) / Stainless Steel (SS) )
SS
Water inlet (plastic / Stainless Steel (SS) )
SS
Weight
6.81kg
10 SERVICE DEPARTMENT
Damaged switches must be replaced by our after-sales service department.
If the connecting cable (or mains plug) is damaged, it must be replaced by a special
connecting cable which is available from our service department. Replacement of the
connecting cable should only be carried out by our service department (see last page) or
by a qualified specialist (qualified electrician).