4
INSTALLATION OVERVIEW
This manual will walk you through the installation of the scoreboard. While care has been taken to
consider the many scenarios for installation, some general information applies to all. Use this guide
as closely as possible to ensure proper installation, as follows:
1. Review the product specifications below to determine your specific installation hardware.
2.
Determine the scoreboard’s location and orientation.
3. Install the mounting poles/I Beams (supplied by the customer).
4. Mount the scoreboard to the poles/I Beams
(mounting hardware supplied by customer).
5. Install the control cable for cable-controlled systems (
not necessary for Wireless Remote
Control systems).
6. Install the electrical service for the scoreboard and the controller.
7. Install any options, such as sponsor panels or protective nets, according to the installation
instructions included with each option package.
8. Test the installed system.
9. Fax/return warranty activation sheet to Scoreboard Service Company at (270) 753-3773.
PRODUCT SPECIFICATIONS
Overall Dimensions:
9’ L x 6’ W x 8” D - shipped in one (1) section
Weight:
Hanging weight = approximately 250 lbs
Shipping weight = approximately 300 lbs.
Mounting Recommendations:
(2)
8” steel I-beams (W8 x 31)
OR
(2) 8” OD galvanized steel poles (schedule 40); Total length
determined by local codes, customer preferred mounting height, and scoreboard options.
Power Requirements:
Scoreboard:
(1) 120-volt, 20-amp, 60 Hz grounded AC circuit connected to a power disconnect switch or
circuit breaker (refer to the wiring diagram on page 9 for instructions on determining the
scoreboard’s power requirements – specific power requirement information is also marked on
the scoreboard’s serial number label, located on the scoreboard)
Keyboard Controller:
(1) 120-volt, 15-amp, 60 Hz grounded AC circuit in a standard duplex outlet (optional if an
internal battery pack was purchased with the controller)
Cable Recommendations (for cable-controlled systems only):
Four conductor cable
– 28 gauge, twisted pair (two pairs), shielded data cable