11. Service and repair work
This section is intended for the qualified
electrician.
Inspecting the energy storage system from
11.1
outside
Is the inlet opening for ventilation on the battery inverter
blocked/clogged (see Chapter 11.4.7)?
Is the room temperature between 5 °C and 30 °C assured
throughout the year (+18 °C is the ideal temperature)?
Clarify with the customer as to how the temperature in the
installation room can be maintained. If necessary, an active
fan has to be installed.
Clarify with the customer whether any additional heat
sources have been installed in the installation room since
installation of the storage system or last maintenance.
Is the wall-mounting stable?
Tighten or replace the screws as necessary.
Checking the system parameters (Service)
11.2
The system parameters are checked via the web interface. To do so,
please observe Chapter 9 and the service booklet.
Checking the online status
11.2.1
On the web interface welcome page, the WWW icon indicates
whether the energy storage system is connected to the VARTA
server (green = online, red = offline).