Technical parameters
3.6
VARTA PULSE 3
Nominal capacity
AC charge power
AC discharge power
Battery inverter structure
Dimensions in mm (W x H x D)
Weight (incl. battery module)
Installation location
Grid connection
Make current
Maximum output residual current
Internal consumption
optimisation
Power measurement
System transport
Packaging in mm (W x H x D)
Grid system fusing
3.3 kWh
1.8 kW
1.6 kW
without isolation transformer
600 x 690 x 190
45 kg
inside the building
240 V AC, 50 Hz
< max. operating current for
input and output
max. 11 A for 100 μs
Automatically controlled
3-phase, via current sensor
horizontally on a pallet
620 x 700 x 210
16 A (B-character)
Table 5: Technical parameters - VARTA pulse 3
VARTA PULSE 6
Nominal capacity
AC charge power
AC discharge power
Battery inverter structure
Dimensions in mm (W x H x D)
Weight (incl. battery modules)
Installation location
Grid connection
Make current
Maximum output residual current
Internal consumption
optimisation
Power measurement
System transport
Packaging in mm (W x H x D)
Grid system fusing
6.5 kWh
2.5 kW
2.3 kW
without isolation transformer
600 x 690 x 190
65 kg
inside the building
240 V AC, 50 Hz
< max. operating current for
input and output
max. 11 A for 100 μs
Automatically controlled
3-phase, via current sensor
vertical on a pallet
620 x 700 x 210
16 A (B-character)
Table 6: Technical parameters - VARTA pulse 6