Technical Specifications 

Model  

VN 1000 dmx 

Gezir 1000 dmx 

Power Supply 

 

 

Power Consumption 

1,000 W 

1,000 W 

Output Volume 

284 m³/min. 

284 m³/min. 

Tank Capacity 

1.7 liters 

2.5 liters 

Fluid Consumption 

49 min./ liter

 

24 min./ liter

 

Weight 

6.6 kg

 

9.8 kg

 

Dimensions (LxWxH)  

435 x 200 x 230 mm

 

370 x 295 x 135 mm

 

Remote Included 

Z-10 Z-10 

Optional Remote 

Z-40, Z-50 

Z-40, Z-50 

Warm-up Time 

4.5 min. 

12 min. 

 
Remote Control Operation 

 

 

Z-10: 10 meter wired remote controller with 6,3 mm jack plug of VARYTEC Fog Machine models VN 1000 
dmx and Gezir 1000 dmx. The red lamp indicates that the unit is receiving power. When the fog machine 
has reached operating temperature the green light on this remote control will light up, indicating that the 
operator may begin fog emission by pressing the red button. The green light flashes during fog machine 
warm-up and re-heating cycles (approx. 1-2 minutes), and stays ON when the machine becomes 
operational. The Z-10 features the “toggle switch’’ function: press once for continuous “ON”, press again to 
release continuous “ON” function 

 

 

Z-40:

 

10 meter wired remote controller with 6,3 mm jack plug for VARYTEC Fog Machine models VN 1000 

dmx and Gezir 1000 dmx. Its two knobs allow the operator to customize fog machine functions by adjusting 
output duration and interval. Press the yellow TIMER-button to activate the timer function. Adjust the 
interval between each fog emission (within the range of 1 second to 250 seconds) by means of the 
INTERVAL control knob. Adjust the duration of each fog emission (within the range of 1 to 15 seconds) by 
means of the DURATION control knob. When pressed, the green FOG button overrides all other control 
functions and activates maximum output. Press the red POWER ON/OFF button for continuous output. 

 

 

Z-50: Wireless remote controller with 6,3 mm jack plug for VARYTEC Fog Machine models VN 1000 dmx 
and Gezir 1000 dmx. A remote operation is possible up to a distance of 50 meters. Keep the red button 
pressed for fogging.

 

 

Z-10, Z-40, Z-50 Remote Controller 

 

 

Summary of Contents for VN 1000 dmx

Page 1: ...1000 dmx BEDIENUNGSANLEITUNG Congratulations on the purchase of your new VARYTEC FOG MACHINE Wir begl ckw nschen Sie zum Kauf Ihres neuen VARYTEC NEBELGER TES Read and save these instructions Bitte l...

Page 2: ...before filling its tank Always keep fog machine in upright position Turn off or unplug the machine when not in use This machine is not water proof If moisture water or fog fluid gets inside the housin...

Page 3: ...ir 1000 dmx Fog Machine make sure that there is no evident damage caused by transportation In the event that the unit s housing or cable is damaged do not plug it in and do not attempt to use it until...

Page 4: ...the unit The machine will stop to fog if the fluid is lower than usable level If you experience low output pump noise or no output at all unplug immediately Check fluid level the external fuse remote...

Page 5: ...achine becomes operational The Z 10 features the toggle switch function press once for continuous ON press again to release continuous ON function Z 40 10 meter wired remote controller with 6 3 mm jac...

Page 6: ...fog liquid from the machine Add cleaning solution to tank Plug unit in and begin warm up 2 Run the unit in a well ventilated area until the tank is almost empty Do not allow the pump to run dry 3 Clea...

Page 7: ...On Off function can be programmed using the DMX controller or the DMX control software being used by lighting and effects operator If Channel A has a value from 0 to 128 the unit is OFF Between the va...

Page 8: ...as set out in the table below The starting address is defined as the first channel from which the device will respond to the controller Please make sure that you do not have any overlapping channels...

Page 9: ...C Nebelger t immer vom Netz zu trennen Achten Sie darauf dass das Nebelger t stets aufrecht installiert ist Wird das Ger t au er Betrieb genommen ist das Ger t auszuschalten oder vom Netz zu trennen D...

Page 10: ...sungen Auspacken und auf Transportsch den untersuchen ffnen Sie den Au enkarton und stellen Sie sicher dass alle Teile die f r den Betrieb des Systems notwendig sind in einem einwandfreien Zustand ein...

Page 11: ...TEC VN 1000 dmx Gezir 1000 dmx Nebelger tes finden Sie unter Bedienung ber eine Fernbedienung Wichtig W hrend des Nebelns immer auf die Fluidtankanzeige achten Der Betrieb eines Nebelger tes ohne Flui...

Page 12: ...die ben tigte Betriebstemperatur erreicht hat leuchtet die gr ne LED auf der Fernbedienung auf Das Ger t ist nun einsatzbereit und der Nebelaussto kann durch Dr cken des roten Knopfes ausgel st werden...

Page 13: ...und 20 Essigs ure durch das System laufen zu lassen Dadurch lassen sich Ablagerungen im Heizelement vermeiden Bitte gehen Sie wie folgt vor 1 Entleeren Sie den Tank vollst ndig F llen Sie die Reinigu...

Page 14: ...anleitung beschrieben Dadurch vermeinden Sie dass Partikel innerhalb der Pumpe oder der Heizung kondensieren 2 Wir empfehlen Ihnen monatlich an der Maschine einen Testlauf durchzuf hren der aus einer...

Page 15: ...ie Ger te k nnen auch ber den DMX Controller oder die DMX software ber das Lichteffektfenster programmiert werden Zwischen den Werten 0 und 128 von Steuerkanal A ist das Ger t aus Zwischen den Werten...

Page 16: ...IP Schalter entsprechend untenstehender Tabelle einstellen Die Startadresse ist der erste Kanal auf den ein Ger t auf Signale vom Controller reagiert Bitte vergewissern Sie sich dass sich die Steuerka...

Page 17: ...Importeur B K Braun GmbH Industriestra e 1 D 76307 Karlsbad www bkbraun com...

Reviews: