17.
Installation manual
A)
Packaging content
The electric preheating element gets delivered
in a box.
Remove the packaging and check the contents:
-
Black power cable
-
Electric preheating element
The appliance should be transported and unpacked with
caution.
Ensure an environmentally friendly way of disposing of
the packaging materials.
B)
Installation conditions
The customer must ensure that the supplied air does not contain any rough contaminants that could
block the built-in preheating element or permanently foul it/cover it. Operation in a particle/dust-free
environment or use of a suitable air filter in front of the preheating element is recommended. Any
unique use beyond the intended uses of the preheating element must be evaluated and assured as
required by the manufacturer.
To determine whether the installation of the preheating element in a specific room is
possible, the following aspects must be taken into account:
The room must be frost-free
The preheating element must be within 2m range from the circuit board of the ventilation unit
(black power cable connection)
The installation must be carried out in accordance with general and local regulations safety and
installation regulations, including ventilation and electricity as well as in accordance with the
instructions in this manual
The following facilities must be present in the room:
- Air duct connections
- (Only relevant to article 11VE44170) 230V ± 10%, single phase, 50Hz socket
C)
Mounting
Installation positioning
The preheating element must be installed on the duct bringing in the air from outside into the
ventilation unit. See the rectangle marked on the image below as an example.
Keep in mind that the max. distance between the preheating element and the circuit board of the
ventilation unit is 2m, this for the cable connection which has to be made between the 2 devices.
The preheating element can be mounted horizontally or vertically.