Trouble Shooting 

 
Valve does not close / open : 

Power available? 

Check voltage. 

 

Compressed air available? 

Check air pressure. 

 

Solenoid defective? 

Check solenoid (manual emergency operation). 

 

 

 

Leak at gate : 

Dirty? 

Clean valve seat and gate. 

 

Gate seal damaged? 

Replace gate if damaged. 

 

Seal compression weak? 

Check air pressure and actuator adjustment. 

 

 

 

Leak at body : 

Flanges leak tight? 

Clean or replace flange O-ring. 

 

Leak at bellows? 

Replace bellows. 

 
 

Repairs 

 
Contact VAT for repairs or maintenance. Please advise the serial No. (F021 . . . . . / . . . . ) marked on the actuator.  
It is individually decided whether the repair can be performed by the customer or has to be carried out by VAT. 
 
Disconnect all supplies (e. g. compressed air, electrical power) for removal/installation of the valve from/into the  
system before doing any repair. 
 

 

Even with disconnected supply, loaded springs and/or air cushions in cylinders are potential hazards. 

 

 

 

Keep fingers and objects away from the valve openings! 

 
Products returned to VAT for repair have to be free of harmful substances such as e.g. toxic, caustic or micro-biological  
ones. For radioactive contaminated products fill in the VAT form «Contamination and Radiation Report» and send it with  
the product. The form is available at VAT. The maximum permissible values indicated in the form must not be exceeded. 
 
 

Warranty 

 

Each product sold by VAT Vakuumventile AG (VAT) is warranted to be free from the manufacturing defects that adversely 
affect the normal functioning thereof during the one-year period immediately following delivery thereof by VAT, provided 
that the same is properly operated under conditions of normal use and that regular, periodic maintenance and service is 
performed or replacements made, in accordance with the instructions provided by VAT. The foregoing warranty shall not 
apply to any product or component that has been repaired or altered by anyone other than an authorized VAT 
representative or that has been subject to improper installation or abuse, misuse, negligence or accident. VAT shall not be 
liable for any damage, loss, or expense, whether consequential, special, incidental, direct or otherwise, caused by, arising 
out of or connected with the manufacture, delivery (including any delay in or failure to deliver), packaging, storage or use 
of any product sold or delivered by VAT shall fail to conform to the foregoing warranty or to the description thereof 
contained herein, the purchaser thereof, as its exclusive remedy, shall upon prompt notice to VAT of any such defect or 
failure and upon the return of the product, part or component in question to VAT at its factory, with transportation charges 
prepaid, and upon VAT's inspection confirming the existence of any defect inconsistent with said warranty or any such 
failure, be entitled to have such defect or failure cured at VAT's factory and at no charge therefor, by replacement or repair 
of said product, as VAT may elect. VAT MAKES NO WARRANTY OR REPRESENTATION OF ANY KIND, EXPRESS OR 
IMPLIED, (INCLUDING NO WARRANTY OR MERCHANTABILITY), EXCEPT FOR THE FOREGOING WARRANTY AND 
THE WARRANTY THAT EACH PRODUCT SHALL CONFORM TO THE DESCRIPTION THEREOF CONTAINED 
HEREIN, and no warranty shall be implied by law. Furthermore, the «Terms of sale» at the back of the price list are 
applicable. 

Summary of Contents for 021 Series

Page 1: ...ication No patented 021 A Read these Installation Operating and Maintenance Instructions and the enclosed General Safety Instructions carefully before you start any other action Actuator 24 w o soleno...

Page 2: ...ed position Feedthrough welded metal bellows Technical Data Leak rate FKM seals valve body 1 10 9 mbar l s 1 seat 1 10 9 mbar l s 1 Leak rate FFKM seals valve body 1 10 8 mbar l s 1 seat 1 10 7 mbar l...

Page 3: ...ITON gate seal FKM VITON Mounting position any Position indicator Contact rating 3 A 50 V DC Compressed air pressure 4 7 bar 55 95 psig overpressure Compressed air connections internal threads M5 with...

Page 4: ...wing must be met under all operating conditions Compressed air connection Compressed air pressure min max overpressure 4 7 bar 55 95 psi Use only clean dry or slightly oiled air Connections Internal t...

Page 5: ...er to the dimensional drawing of the product to ensure it is properly specified for the application Normal operation Valve with pneumatic actuator Valve is opened and closed pneumatically Admissible t...

Page 6: ...69 Haag Switzerland Tel 41 81 771 61 61 Fax 41 81 771 48 30 Email reception vat ch http www vat ch 205440EC 2003 04 14 6 12 Emergency operation at power failure In case of power failure valve can be a...

Page 7: ...ator assembly carefully 4 Loosen screws 44 by 1 turn to withdraw gate from shafts 5 Clean or replace gate reassemble in reverse direction Tighten gate screws 44 with 5 Nm Replacing Bellows 1 Remove ga...

Page 8: ...2 bar air pressure To check this 1 Reduce air pressure below 0 5 bar 2 Command valve in closed position 3 Increase air pressure until a clicking sound indicates the mechanical locking Adjustment of C...

Page 9: ...VATSEAL optional SS body only 32 x 222 76168 R1 78175 R1 N 5100 266 N 5100 263 82180 01 46 x 236 77006 R1 78201 R1 N 5100 266 N 5100 263 82180 01 50 x 336 94027 R1 96031 R1 N 5100 275 N 5100 273 8169...

Page 10: ...fluoro black 81063 R1 78510 R1 Silicone red 79416 R1 82625 R1 Silicone transparent 85630 R1 Aluminium SC 1107 205580 205581 204585 VITON 80499 01 82510 01 95842 R1 Chemraz 630 99424 R1 101367 R1 Chemr...

Page 11: ...ste m ISO 9001 EN 29001 Installation Operating and Maintenance Instructions Series 021 VAT Vakuumventile AG CH 9469 Haag Switzerland Tel 41 81 771 61 61 Fax 41 81 771 48 30 Email reception vat ch http...

Page 12: ...the manufacturing defects that adversely affect the normal functioning thereof during the one year period immediately following delivery thereof by VAT provided that the same is properly operated unde...

Reviews: