INSTALLATION
Series 590
36/56
Edition 2013-05-13
298292EB
Setup function
Command
Acknowledgement
(within 10ms after reception of command)
Description
VALVE SPEED
Set
[V:][00xxxx][CR][LF]
[V:][CR][LF]
Get
[i:68][CR][LF]
[i:68][0000xxxx][CR][LF]
data length 6 characters starting with double zero for writing
8 characters starting with quadruple zero for reading
xxxx
valve speed,
1
...
1000
(1 = min. speed, 1000 = max. speed)
This command allows changing the actuating speed of the valve plate. Speed selection is
effective for pressure control and position control. Open valve and close valve are always
done with max. speed.
Pay attention:
Refer to chapter: «Valve speed adjustment» for details.
RESET
Set
[c:82][xx][CR][LF]
[c:82][CR][LF]
data length 2 characters
xx
00
= reset service request bit from WARNINGS
01
= reset FATAL ERROR (restart control unit)
This function resets warnings and errors.
Table 4-12