Series 590
OPERATION
298292EB
Edition 2013-05-13
39/56
When communication to service port is interrupted the valve will change to remote
operation. So when service cable will be disconnected or software will be shut down,
the valve returns automatically to remote operation. This may result in an immediate
movement of the valve depending on remote control.
Refer to chapter: «Accessories» for ordering numbers of service cable, software and Service Box 2.
5.1.2
Remote operation
This product is equipped with an RS232 interface to allow for remote operation. See section «RS232
Interface» for details. ‘Control View’ software, 'Control Performance Analyzer' software or 'Service Box
2' may be used for monitoring during remote control.
In case ‘Control View’ or ‘Control Performance Analyzer’ software is connected to
valve make sure ‘REMOTE’ button is pushed to enable for remote operation. In case
Service Box 2 is connected to valve make sure the LED on button ‘LOCAL’ is OFF for
remote operation.
5.2
Close valve
The valve is completely closed when the stop is reached. A stopper is implemented in the leak valve
to prevent over tightening of the seat in the closed position.
Local operation:
(‘Control View’, ‘Control Performance Analyzer’ or
‘Service Box 2‘)
Remote operation:
(Refer to chapter: «RS232 control commands»
for details.)
Push CLOSE button
Send CLOSE VALVE
5.3
Open valve
The valve is completely open when the mechanical stop is reached.
Local operation:
(‘Control View’, ‘Control Performance Analyzer’ or
‘Service Box 2‘)
Remote operation:
(Refer to chapter: «RS232 control commands»
for details.)
Push OPEN button
Send OPEN VALVE